Element 4.27
Refrigeration and cold chains for food and medicine
- Sheet
- 4.27
- Chapter
- 4 Food and farming
- State
- Drafted
- Release
- 16 November 2026
- Editor
- Contributed by Praecise as open research
- Reviewers
- To be named at review
- Safety
- S2, as the chapter
- Licence
- CC BY-SA 4.0
- Resources
- 7
The element
- Requirement
Perishable food is kept cool from harvest to plate so that less is lost, and vaccines and medicines are kept within their required range in equipment that has been tested for the climate and the power supply, including where there is no grid.
- How to tell
Vaccine refrigerators are chosen from equipment prequalified by WHO, whose E003 specifications divide refrigerators by power source, from mains compression to solar direct drive without a battery WHO PQS documents: E003 refrigerators and freezers for vaccines. Temperatures in every cold store are logged. For produce, losses before and after storage are counted; postharvest practice follows the handling guidance in Small-Scale Postharvest Handling Practices: A Manual for Horticultural Crops (4th edition). Refrigerant systems are checked against ISO 5149 ISO 5149-1, Refrigerating systems and heat pumps: Safety and environmental requirements, Part 1: Definitions, classification and selection criteria.
- Options
Evaporative coolers. Clay-pot coolers for households and brick chambers for cooperatives. MIT D-Lab measured drops of more than 8 degrees C in real use in Mali and longer shelf life for tomatoes, cucumbers, eggplant, cabbage and hot peppers; brick chambers outperformed straw and sack ones, and all worked best in hot, dry weather MIT researchers release evaluation of low-cost cooling devices in Mali. No electricity; not for vaccines.
Solar direct-drive refrigerators. WHO PQS has a category for solar direct drive without battery storage and one with an ancillary battery WHO PQS documents: E003 refrigerators and freezers for vaccines. Fits clinics without reliable power.
Mains and battery-backed refrigerators. Mains compression, ice-lined and intermittent-mains categories in the same catalogue WHO PQS documents: E003 refrigerators and freezers for vaccines.
Cold rooms. For a cooperative's produce or a community store. Refrigerant choice follows the HFC phase-down The Kigali Amendment (2016): the amendment to the Montreal Protocol agreed by the Twenty-Eighth Meeting of the Parties; propane systems now have higher allowed charges in household-type units Adoption of long-awaited standard for flammable refrigerants (IEC 60335-2-40, approved 2022). No open source with documented results for off-grid cold rooms or community ice making was opened in this work.
- Settled, open, contested
Settled. Vaccines need tested equipment; improvised cooling is not acceptable for them WHO PQS documents: E003 refrigerators and freezers for vaccines. Evaporative cooling works in hot, dry conditions MIT researchers release evaluation of low-cost cooling devices in Mali. Refrigerant circuits are at safety level S2 to S3 and are handled by certified people; this page gives no procedure. Open. Why proven evaporative coolers are not more widely used; D-Lab's study notes users watered them less once the rains began MIT researchers release evaluation of low-cost cooling devices in Mali. Contested. Battery or no battery in solar refrigerators: direct drive stores cold instead of electricity and avoids battery replacement; a battery adds autonomy and cost WHO PQS documents: E003 refrigerators and freezers for vaccines.
The four stages
Learn: Small-Scale Postharvest Handling Practices: A Manual for Horticultural Crops (4th edition) MIT researchers release evaluation of low-cost cooling devices in Mali. Design: list what must be cooled, to what temperature and for how long; vaccines from the WHO PQS catalogue only WHO PQS documents: E003 refrigerators and freezers for vaccines. Build: evaporative chambers can be built locally MIT researchers release evaluation of low-cost cooling devices in Mali; refrigeration circuits by certified technicians ISO 5149-1, Refrigerating systems and heat pumps: Safety and environmental requirements, Part 1: Definitions, classification and selection criteria. Deploy: log temperatures daily; act on every excursion.
Resources at each stage
1 Learn
Understand
- Small-Scale Postharvest Handling Practices: A Manual for Horticultural Crops (4th edition) Guide, S2
- MIT researchers release evaluation of low-cost cooling devices in Mali Case study, S1
- Key measures could slash predicted 2050 emissions from cooling sector (Global Cooling Watch 2023) Paper, S0
- The Kigali Amendment (2016): the amendment to the Montreal Protocol agreed by the Twenty-Eighth Meeting of the Parties Framework, S0
2 Design
Size and choose
- Adoption of long-awaited standard for flammable refrigerants (IEC 60335-2-40, approved 2022) Standard, S3
- ISO 5149-1, Refrigerating systems and heat pumps: Safety and environmental requirements, Part 1: Definitions, classification and selection criteria Standard, S3
- MIT researchers release evaluation of low-cost cooling devices in Mali Case study, S1
- The Kigali Amendment (2016): the amendment to the Montreal Protocol agreed by the Twenty-Eighth Meeting of the Parties Framework, S0
- WHO PQS documents: E003 refrigerators and freezers for vaccines Standard, S2
3 Build
Build or obtain
- Adoption of long-awaited standard for flammable refrigerants (IEC 60335-2-40, approved 2022) Standard, S3
- ISO 5149-1, Refrigerating systems and heat pumps: Safety and environmental requirements, Part 1: Definitions, classification and selection criteria Standard, S3
- Small-Scale Postharvest Handling Practices: A Manual for Horticultural Crops (4th edition) Guide, S2
- MIT researchers release evaluation of low-cost cooling devices in Mali Case study, S1
- WHO PQS documents: E003 refrigerators and freezers for vaccines Standard, S2
4 Deploy
Install, run and measure
What changes between 30 adults and 300 people
For 30 adults, household refrigerators or one shared cold store, plus evaporative coolers for produce in dry climates, cover most needs. For 300 people a health post with prequalified vaccine refrigeration becomes necessary WHO PQS documents: E003 refrigerators and freezers for vaccines, and a growers' cooperative may justify a brick evaporative chamber or a cold room MIT researchers release evaluation of low-cost cooling devices in Mali. UNEP's Cool Coalition counts about 1.2 billion people in Africa and Asia without access to cooling Key measures could slash predicted 2050 emissions from cooling sector (Global Cooling Watch 2023).
Reference designs
Open for contributions Designs with drawings, specifications and a bill of materials. Add to it
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
Depends on, and completes
It is one of 27 elements that complete Food and farming.
The standing questions
Who pays for the cold store and its power. Who reads the thermometers every day. Who decides whose produce goes in first.
Environments
Hot deserts and dry savanna. Evaporative cooling at its best MIT researchers release evaluation of low-cost cooling devices in Mali. Humid tropics. Evaporative cooling weakens as humidity rises (the Mali rainy season) MIT researchers release evaluation of low-cost cooling devices in Mali; mechanical or solar refrigeration is needed. Off-grid settings anywhere. Solar direct-drive vaccine refrigerators WHO PQS documents: E003 refrigerators and freezers for vaccines. Arctic cold, islands, high altitude, flood plains. No source found.
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.