Element 8.20
Priority medical devices and their regulation
- Sheet
- 8.20
- Chapter
- 8 Health and care
- State
- Drafted
- Release
- 16 November 2026
- Editor
- Contributed by Praecise as open research
- Reviewers
- To be named at review
- Safety
- S3, as the chapter
- Licence
- CC BY-SA 4.0
- Resources
- 9
The element
- Requirement
Any medical device used in the community's care is suitable for the level of care, obtained through the health service or a legal supplier, authorised where the law requires, maintained, and used by people trained to use it. This page describes how a community organises; it gives no clinical instruction.
- How to tell
The clinic or service can show where each device on site came from, that it is authorised for the use made of it, and who maintains it. Selection draws on WHO's lists of priority medical devices. WHO publishes lists for reproductive, maternal, newborn and child health (2016), cancer management (2017), the COVID-19 response (2020) and cardiac diseases, stroke and diabetes (2021), and an evidence-based selection method from 2010 (Prioritizing medical devices). The 2021 list for heart disease and diabetes names more than 500 devices needed at every level from primary care to specialised hospitals (WHO launches List of Priority Medical Devices for management of cardiovascular diseases and diabetes).
- Options
Devices supplied by the health service. The default. The service brings authorised devices and their maintenance.
Selection from WHO's catalogue. MeDevIS is WHO's open-access database of devices on its priority lists and related products, made for ministries, hospital managers, clinicians and biomedical engineers (Prioritizing medical devices). It can be browsed by healthcare unit, service delivery platform, device type and whether a device is capital, reusable or single use (WHO Priority list of medical devices information system (MeDevIS)).
A first-level care list built from modules. PAHO's list of priority medical devices for the first level of care in the Americas, third version of November 2021, uses modules that a centre adds only for the services it offers (List of priority medical devices for the first level of care for the countries of the Americas. Third version, November 2021).
National context. WHO's Global atlas of medical devices 2022 gives country profiles on device policies, regulation, lists, inventories, nomenclature and biomedical engineering resources (Global atlas of medical devices 2022). It is the place to find what a country already requires.
Open-source hardware and open quality systems. Some open designs exist for laboratory work. The OpenFlexure Microscope project keeps a section on regulatory compliance and medical use (OpenFlexure Microscope). An open design is not, by being open, authorised for clinical use. In January 2026 a clinical scientific computing team at a London hospital trust published its ISO 13485 quality management system as an open template; its release states that the system had passed 18 internal audits and three external ISO 13485 audits by two UK notified bodies (CSC open-sources its ISO 13485 quality management system).
Software as a medical device. Apps and software that diagnose, monitor or treat are regulated as devices in many places; in Germany, a prescribed digital health application must be a CE-marked medical device of risk class I or IIa (Digital Health Applications (DiGA)). WHO sets out regulatory considerations for software that uses artificial intelligence (Regulatory considerations on artificial intelligence for health).
- Settled, open, contested
Settled. Medical devices are chosen for the level of care and authorised under national law. Clinical use of a device is a matter for qualified staff.
Open. How open-source medical hardware reaches authorisation. No source opened in this work describes a general route; it depends on the national regulator.
Contested. Whether communities should build devices locally. Local building gives repair and cost advantages; without authorisation and quality systems it carries clinical and legal risk.
The four stages
Learn: how WHO selects priority devices (Prioritizing medical devices). Design: with the health service, list what each care level needs (WHO Priority list of medical devices information system (MeDevIS), WHO launches List of Priority Medical Devices for management of cardiovascular diseases and diabetes). Build: power, clean space and storage the devices need (domains 5 and 6). Deploy: a maintenance log, a named person for each device, and return of faulty devices to the supplier.
Resources at each stage
1 Learn
Understand
- Digital Health Applications (DiGA) Framework, S2
- OpenFlexure Microscope Reference design, S1
- Regulatory considerations on artificial intelligence for health Guide, S2
- Global atlas of medical devices 2022 Dataset, S1
- Prioritizing medical devices Guide, S2
2 Design
Size and choose
- CSC open-sources its ISO 13485 quality management system Repository, S2
- List of priority medical devices for the first level of care for the countries of the Americas. Third version, November 2021 Guide, S2
- Regulatory considerations on artificial intelligence for health Guide, S2
- WHO Priority list of medical devices information system (MeDevIS) Dataset, S2
- WHO launches List of Priority Medical Devices for management of cardiovascular diseases and diabetes Guide, S2
- Prioritizing medical devices Guide, S2
3 Build
Build or obtain
- CSC open-sources its ISO 13485 quality management system Repository, S2
- OpenFlexure Microscope Reference design, S1
What changes between 30 adults and 300 people
Thirty adults hold first aid equipment (8.2) and devices people use for themselves. Three hundred people with a visiting clinic need a room equipped to the service's list, reliable power, and someone responsible for device care with the service's biomedical engineer.
Reference designs
-
Reference design
An open-source, 3D-printable laboratory microscope with a motorised flexure stage, built around a Raspberry Pi camera.
External resource. Not made or verified by Public ProtocolMaturity: Not assessedSafety S1Listed 16 November 2026
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
| Resource | Type | Origin | Maturity | Safety | Licence, as stated at its source |
|---|---|---|---|---|---|
| Digital Health Applications (DiGA) | Framework | External | Established | S2 | Not stated on the page opened |
| CSC open-sources its ISO 13485 quality management system | Repository | External | Working | S2 | Not stated on the page opened |
| OpenFlexure Microscope | Reference design | External | Not assessed | S1 | Website content CC BY-SA 4.0; hardware licence not stated on the page opened |
| List of priority medical devices for the first level of care for the countries of the Americas. Third version, November 2021 | Guide | External | Established | S2 | CC BY-NC-SA 3.0 IGO |
| Regulatory considerations on artificial intelligence for health | Guide | External | Established | S2 | CC BY-NC-SA 3.0 IGO |
| Global atlas of medical devices 2022 | Dataset | External | Established | S1 | CC BY-NC-SA 3.0 IGO |
| WHO Priority list of medical devices information system (MeDevIS) | Dataset | External | Working | S2 | Not stated on the page opened |
| WHO launches List of Priority Medical Devices for management of cardiovascular diseases and diabetes | Guide | External | Established | S2 | Not stated on the page opened |
| Prioritizing medical devices | Guide | External | Established | S2 | Not stated on the page opened |
Depends on, and completes
It is one of 22 elements that complete Health and care.
The standing questions
Who pays for devices and their upkeep. Who maintains them. Who decides what is used on patients: the health service and the regulator.
Environments
No source opened in this work describes how priority device needs change by setting. Islands and coasts, Arctic cold, hot deserts, tropical humid forest, temperate forest, high altitude, flood plains and other harsh settings: no source found. Operating conditions follow each maker's instructions.
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History