Public Protocol
Platform

Element 5.17

Hybrid systems, sizing tools and community microgrids

Sheet
5.17
Chapter
5 Energy
State
Drafted
Release
16 November 2026
Editor
Contributed by Praecise as open research
Reviewers
To be named at review
Safety
S3, as the chapter
Licence
CC BY-SA 4.0
Resources
16

The element

Requirement

The community chooses its mix of sources, storage and backup by simulating a full year, hour by hour, with open data and open tools before it buys anything. Where its system can run as an island, the controller and inverters are specified so that the system can form and hold its own voltage and frequency, and the design is signed off by a qualified engineer.

How to tell

There is a model that uses hourly resource data for the site, a demand profile, and the costs of each option, and its result is written down with the assumptions. Resource data comes from public sources with known licences: the Global Solar Atlas and the Global Wind Atlas are licensed CC BY 4.0 (Global Solar Atlas GIS data (World Bank Data Catalog)) (Global Wind Atlas); Renewables.ninja hourly output is CC BY-NC 4.0, with commercial use by arrangement (Renewables.ninja). The microgrid controller is specified against IEEE 2030.7, which covers the control functions of any microgrid and includes test procedures (IEEE 2030.7-2017 IEEE Standard for the Specification of Microgrid Controllers). Off-grid systems follow the IEC 62257 series (IEC TS 62257-100:2022 Renewable energy off-grid systems - Part 100: Overview of the IEC 62257 series).

Options

Least-cost sizing for a small island system. MicroGridsPy sizes and dispatches isolated micro-grids (MicroGridsPy); RAMP builds the demand profile (RAMP).

Network and multi-energy optimisation. PyPSA, under the MIT licence, optimises dispatch, power flow and capacity expansion and runs with open solvers such as HiGHS (PyPSA: Python for Power System Analysis).

Detailed performance and finance. The System Advisor Model, BSD-3-Clause, models several renewable technologies with financial models (System Advisor Model (SAM)); pvlib python gives open, benchmarked PV models (pvlib python).

Grid-forming inverters. Inverters that set voltage and frequency themselves, instead of following a grid. The UNIFI consortium's consensus specifications set system-level and inverter-level requirements, can include black start, and are to be the basis for IEEE 2800.1 (UNIFI Consortium: Universal Interoperability for Grid-Forming Inverters).

Proven island hybrids. King Island in Australia combined wind, solar and biodiesel with batteries, a diesel-based uninterruptible supply and advanced control to supply over 65% of its annual energy from renewables; its lessons fed later island projects (King Island Renewable Energy Integration Project).

Settled, open, contested

Settled. Simulate before buying. An islanded system that can back-feed a grid line is an S3 hazard to line workers; the network operator's rules apply (5.8).

Open. Interoperability of grid-forming inverters from different makers; that is the problem the UNIFI consortium exists to solve (UNIFI Consortium: Universal Interoperability for Grid-Forming Inverters).

Contested. Open tools or commercial sizing software: transparency and no fee against support and familiarity to engineers. The open tools named here are used in research and practice; no comparison was opened.

The four stages

Learn: (King Island Renewable Energy Integration Project) (UNIFI Consortium: Universal Interoperability for Grid-Forming Inverters). Design: data from (Global Solar Atlas GIS data (World Bank Data Catalog)) (Global Wind Atlas) (Renewables.ninja) (PVGIS) (Open-Meteo); demand from (RAMP); sizing with (MicroGridsPy) or (PyPSA: Python for Power System Analysis); detail with (System Advisor Model (SAM)) (pvlib python). Build: controller to (IEEE 2030.7-2017 IEEE Standard for the Specification of Microgrid Controllers); installation by qualified people to the IEC 62257 series (IEC TS 62257-100:2022 Renewable energy off-grid systems - Part 100: Overview of the IEC 62257 series); this page gives no wiring or commissioning procedure. Deploy: energy management and logging (OpenEMS) (OpenEnergyMonitor), and a yearly re-run of the model with measured data.

Resources at each stage

What changes between 30 adults and 300 people

For 30 adults, one simulation of solar, storage and a backup generator, checked by the installer, is enough. For 300 people, the model must include the network, several sources and a growth case, and the controller and grid-forming capability become specified items in the purchase.

Reference designs

Open for contributions Designs with drawings, specifications and a bill of materials. Add to it

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
King Island Renewable Energy Integration ProjectCase studyExternalReplicatedS3Not stated on the page opened
Global Solar Atlas GIS data (World Bank Data Catalog)DatasetExternalEstablishedS0Creative Commons Attribution 4.0
Global Wind AtlasDatasetExternalEstablishedS0Creative Commons Attribution 4.0 (stated on the World Bank Data Catalog entry for version 3.0)
IEC TS 62257-100:2022 Renewable energy off-grid systems - Part 100: Overview of the IEC 62257 seriesStandardExternalEstablishedS2Not stated on the page opened
IEEE 2030.7-2017 IEEE Standard for the Specification of Microgrid ControllersStandardExternalEstablishedS3Not stated on the page opened
MicroGridsPyToolExternalNot assessedS0European Union Public Licence: the README text cites v1.1 and the repository lists EUPL-1.2
System Advisor Model (SAM)ToolExternalEstablishedS0BSD-3-Clause (the bundled Sandia stepwise and LHS libraries are under LGPL)
Open-MeteoDatasetExternalNot assessedS0Data: CC BY 4.0. Code: AGPLv3. Free non-commercial use up to 10,000 calls a day.
OpenEMSToolExternalEstablishedS2Edge and backend: EPL-2.0. Interface: AGPL-3.0.
OpenEnergyMonitorToolExternalNot assessedS2Not stated on the pages opened
PVGISToolExternalEstablishedS0Not stated on the tool page opened
pvlib pythonLibraryExternalEstablishedS0BSD 3-clause
PyPSA: Python for Power System AnalysisLibraryExternalEstablishedS0MIT
RAMPToolExternalNot assessedS0EUPL-1.2
Renewables.ninjaToolExternalEstablishedS0Creative Commons Attribution-NonCommercial 4.0 International (data); commercial use by arrangement with the operators
UNIFI Consortium: Universal Interoperability for Grid-Forming InvertersFrameworkExternalWorkingS3All rights reserved by the UNIFI Consortium (copyright notice on the page)

Depends on, and completes

Depends on 5.1, 5.2, 5.3, 5.4, 5.8.

It is one of 23 elements that complete Energy.

The standing questions

Who builds and keeps the model. Who chooses the assumptions. Who signs the design.

Environments

Islands and coasts. King Island ran a high-renewable hybrid with storage and control (King Island Renewable Energy Integration Project). The Global Wind Atlas 4.0 covers offshore economic zones (Global Wind Atlas).

Arctic cold. No source found for hybrid sizing specific to arctic settings.

Hot deserts. No source found.

Tropical humid forest. No source found.

Temperate forest. No source found.

High altitude. No source found.

Flood plains. No source found.

Other harsh settings. No source found.

Safety

State and evidence

Drafted

An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.

Evidence from a real place or system is recorded here, with what did not work. What the states mean

History