Element 6.13
Lighting, light pollution and noise
- Sheet
- 6.13
- Chapter
- 6 Shelter and construction
- State
- Drafted
- Release
- 16 November 2026
- Editor
- Contributed by Praecise as open research
- Reviewers
- To be named at review
- Safety
- S1, as the chapter
- Licence
- CC BY-SA 4.0
- Resources
- 5
The element
- Requirement
Homes, workplaces and paths have enough light for safe use, from products that meet a recognised quality standard. Outdoor light does not spill needlessly into the night sky. Night-time and classroom noise stay within WHO guidance.
- How to tell
- Off-grid lighting kits are certified. VeraSol, which grew out of Lighting Global Quality Assurance, certifies that a solar kit meets internationally recognised standards for quality, durability and truthful advertising, and lists certified products (VeraSol). Lighting Global says it developed the first test methods and quality standards for pico-products and solar home systems up to 350 Wp (Lighting Global Quality Assurance).
- Noise in bedrooms at night stays below 30 dB(A) for good sleep. Classrooms stay below 35 dB(A), and annual average night noise outside bedrooms below 40 dB(A). These are WHO Europe's figures (Noise (WHO Europe fact sheet)).
- Planning for roads, generators, workshops and leisure uses WHO's 2018 noise guidelines, which WHO says can apply beyond Europe (Environmental noise guidelines for the European Region).
- Options
- Certified solar lighting where there is no grid or a weak one (VeraSol).
- Grid or community-grid lighting under domain 5.
- Low-spill outdoor lighting. Light only where and when needed. A citizen-science study found the sky brightening by about 7 to 10 per cent a year from 2011 to 2022 (Citizen scientists report global rapid reductions in the visibility of stars from 2011 to 2022). No design standard for outdoor lighting was opened in this work.
- Separating noise from sleep. Place generators, workshops and roads away from bedrooms and classrooms in the land-use plan (1.4), against the WHO levels (Noise (WHO Europe fact sheet)).
- Settled, open, contested
Settled: WHO Europe gives night and classroom noise figures (Noise (WHO Europe fact sheet)). Open: the 2018 guidelines' numerical levels for road, rail, aircraft, wind turbine and leisure noise were not read in this work and should be added from the full document (Environmental noise guidelines for the European Region). Contested: the study found sky brightening faster than satellites show, and explains the gap by changes in the spectrum and angle of emitted light (Citizen scientists report global rapid reductions in the visibility of stars from 2011 to 2022).
The four stages
- Learn: Noise (WHO Europe fact sheet), Citizen scientists report global rapid reductions in the visibility of stars from 2011 to 2022.
- Design: zone noisy uses in the plan (Environmental noise guidelines for the European Region); specify certified lighting (VeraSol).
- Build: fit lighting under the electrical rules of domain 5.
- Deploy: measure night noise where people complain, and check outdoor lights are needed.
Resources at each stage
1 Learn
Understand
2 Design
Size and choose
- Lighting Global Quality Assurance Standard, S1
- VeraSol Standard, S1
- Noise (WHO Europe fact sheet) Reference design, S1
- Environmental noise guidelines for the European Region Standard, S1
What changes between 30 adults and 300 people
At 30 adults, certified household kits and a few path lights may be all that is needed. At 300 people, roads, shared workshops and a school bring the WHO noise figures for bedrooms and classrooms into the site plan (Noise (WHO Europe fact sheet)). No source read gives costs.
Reference designs
-
Reference design
A WHO Europe fact sheet (2011) giving less than 30 dB(A) in bedrooms at night for good sleep, below 35 dB(A) in classrooms, and less than 40 dB(A) annual average night noise outside bedrooms; it cites about 40 per cent of the EU population exposed to road noise above 55 dB(A).
External resource. Not made or verified by Public ProtocolMaturity: EstablishedSafety S1Listed 16 November 2026
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
| Resource | Type | Origin | Maturity | Safety | Licence, as stated at its source |
|---|---|---|---|---|---|
| Citizen scientists report global rapid reductions in the visibility of stars from 2011 to 2022 | Paper | External | Replicated | S0 | Not stated on the page opened |
| Lighting Global Quality Assurance | Standard | External | Established | S1 | Not stated on the page opened |
| VeraSol | Standard | External | Established | S1 | Not stated on the page opened |
| Noise (WHO Europe fact sheet) | Reference design | External | Established | S1 | Not stated on the page opened |
| Environmental noise guidelines for the European Region | Standard | External | Established | S1 | Not stated on the page opened |
Depends on, and completes
It is one of 22 elements that complete Shelter and construction.
The standing questions
Who pays for lighting and its upkeep. Who decides which outdoor lights stay on at night. Who decides where noisy work takes place.
Environments
No source found for any setting.
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.