Public Protocol
Platform

Element 6.15

Passive heating and cooling

Sheet
6.15
Chapter
6 Shelter and construction
State
Drafted
Release
16 November 2026
Editor
Contributed by Praecise as open research
Reviewers
To be named at review
Safety
S1, as the chapter
Licence
CC BY-SA 4.0
Resources
6

The element

Requirement

Each building keeps its occupants within a healthy temperature range for as many hours of the year as its climate allows without machines, and stays survivable through a heatwave or a cold spell during a power cut. Passive measures are designed in before any heating or cooling machine is sized.

How to tell

Indoor temperature is logged in the hardest season. For cold, UNHCR holds 15 to 19 degrees C indoors as its range Emergency shelter standard, and WHO's housing guidelines set recommendations on low and high indoor temperatures WHO Housing and health guidelines. For heat, the Annex 80 field studies report hours of exceedance above 26 degrees C, an indoor overheating degree and passive survivability (safe indoor conditions with no active cooling) as their indicators; one Vienna residential building recorded 1,245 hours a year above 26 degrees C Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80).

Options

Reduce heat gains. Annex 80 lists glazing, shading, cool envelope materials, evaporative surfaces such as green roofs and roof ponds, ventilated façades and thermal mass Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80). Cool roofs and walls save most cooling energy on older buildings in hot-summer climates with mild winters, and can add heating energy in cold weather Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80).

Night ventilation. Opening windows when outside air is cooler. In an Annex 80 simulation of a Los Angeles house under 2050 weather, window opening cut heat stress by 26 to 36% and cooling electricity by 18 to 37%; Annex 80 calls night ventilation resilient because it needs no energy Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80). WHO gives the same household advice: open at night, close and shade by day Heat and health (WHO fact sheet).

Earth and water coupling. Earth-air heat exchangers (earth tubes) in moderate climates show peak cooling of about 45 W per square metre of ground at 32 degrees C outdoors; horizontal earth loops give 17 to 35 W per metre of pipe Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80).

Personal cooling. Ceiling fans and personal devices cool people, not rooms Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80). WHO advises fans only below 40 degrees C Heat and health (WHO fact sheet).

Sky radiative cooling. Night-sky cooling is in the Annex 80 review Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80); daytime radiative materials are still at prototype stage (see frontier) Hierarchically structured passive radiative cooling ceramic with high solar reflectivity.

Settled, open, contested

Settled. Reduce gains first; passive measures keep working in a power cut. Open. How occupant behaviour changes results: Annex 80 names it a major factor in ventilative cooling Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80). Contested. Cool, reflective envelopes in climates with cold winters: they cut summer gains and can raise winter heating Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80).

What changes between 30 adults and 300 people

For 30 adults, one shared building can be oriented, shaded and ventilated by design, and occupants can be taught when to open and close. For 300 people layout matters: Annex 80 found the limits of purely building-level measures and named outdoor spaces, water, planting and the heat of the settlement itself as the next step Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80). At this scale passive design is also the cheapest cooling; UNEP's Cool Coalition estimates passive cooling could curb global growth in cooling demand to 2050 by 24% Key measures could slash predicted 2050 emissions from cooling sector (Global Cooling Watch 2023).

Reference designs

Open for contributions Designs with drawings, specifications and a bill of materials. Add to it

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80)FrameworkExternalReplicatedS0© Copyright Institute of Building Research & Innovation 2024. No part of this publication may be reproduced without prior written permission.
Hierarchically structured passive radiative cooling ceramic with high solar reflectivityPaperExternalPrototypeS0© 2023 American Association for the Advancement of Science. All rights reserved.
Key measures could slash predicted 2050 emissions from cooling sector (Global Cooling Watch 2023)PaperExternalEstablishedS0Not stated on the page opened
Emergency shelter standardStandardExternalEstablishedS2Not stated on the page opened
Heat and health (WHO fact sheet)GuideExternalEstablishedS2Not stated on the page opened
WHO Housing and health guidelinesGuideExternalEstablishedS1CC BY-NC-SA 3.0 IGO

Depends on, and completes

Depends on 6.3, 5.5.

It is one of 22 elements that complete Shelter and construction.

The standing questions

Who pays for shading and mass that cost more at the start. Who opens and closes the building at night. Who decides the layout that shades the streets.

Environments

Hot deserts. Night ventilation and evaporative surfaces suit dry heat Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80). Humid tropics. Removing humidity is a separate task; Annex 80 treats dehumidification as its own technology group Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80). Arctic cold and temperate forest. Indoor temperature targets from UNHCR and WHO apply Emergency shelter standard WHO Housing and health guidelines; no measured passive-heating source was opened in this work. Islands, high altitude, flood plains. No source found.

Safety

State and evidence

Drafted

An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.

Evidence from a real place or system is recorded here, with what did not work. What the states mean

History