The element
- Requirement
Every occupied room gets enough outdoor air to dilute what people, cooking, heating and materials release; no room is filled with smoke from solid fuel or kerosene; and in tight, insulated buildings ventilation is provided by design rather than left to leaks.
- How to tell
Ventilation is designed to a recognised standard: ASHRAE 62.2 for homes, which requires whole-house mechanical ventilation running continuously or intermittently ANSI/ASHRAE Standard 62.2-2022, Ventilation and Acceptable Indoor Air Quality in Residential Buildings (fact sheet), and ASHRAE 62.1 for other occupied spaces, which sets minimum rates and allows a prescriptive, a performance or a natural ventilation route ANSI/ASHRAE Standard 62.1-2022, Ventilation and Acceptable Indoor Air Quality (fact sheet). WHO's roadmap gives the questions to ask and the steps to reach recommended levels in health-care, non-residential and residential settings Roadmap to improve and ensure good indoor ventilation in the context of COVID-19. Outdoor and indoor pollutant levels are judged against the WHO air quality guidelines WHO global air quality guidelines: particulate matter (PM2.5 and PM10), ozone, nitrogen dioxide, sulfur dioxide and carbon monoxide. No kitchen or room burns unprocessed coal or kerosene WHO Guidelines for indoor air quality: Household fuel combustion.
- Options
Natural ventilation. Openings sized and placed for cross or stack flow; a recognised compliance route in ASHRAE 62.1 ANSI/ASHRAE Standard 62.1-2022, Ventilation and Acceptable Indoor Air Quality (fact sheet). Free to run; depends on weather and on people opening windows.
Mechanical extract and whole-house ventilation. Required in homes under 62.2 ANSI/ASHRAE Standard 62.2-2022, Ventilation and Acceptable Indoor Air Quality in Residential Buildings (fact sheet).
Balanced ventilation with heat recovery. Supply and extract fans with a heat exchanger that warms incoming air in winter and cools it in summer; one Annex 80 field study in Vienna combined heat recovery with a ground heat exchanger on its supply air Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80). No open source with measured recovery efficiencies was opened in this work.
Clean combustion or none. WHO counts solar, electricity, biogas, LPG, natural gas, alcohol fuels and biomass stoves that meet its emission targets as clean at the point of use, and asks that cooking, heating and lighting be addressed together Household air pollution (WHO fact sheet).
- Settled, open, contested
Settled. Smoke from solid fuels and kerosene harms health Household air pollution (WHO fact sheet). Combustion indoors is at safety level S2: carbon monoxide and fire are the hazards; flues and alarms are fitted by qualified people and this page gives no procedure. Open. How much ventilation tight, low-energy homes need in practice; ASHRAE notes jurisdictions often adopt only part of 62.1, leaving out operation and maintenance ANSI/ASHRAE Standard 62.1-2022, Ventilation and Acceptable Indoor Air Quality (fact sheet). Contested. Natural or mechanical ventilation in a new small building: natural needs no power and no parts; mechanical with heat recovery saves heat and works when windows stay shut.
The four stages
Learn: Household air pollution (WHO fact sheet) Roadmap to improve and ensure good indoor ventilation in the context of COVID-19. Design: choose a route under ANSI/ASHRAE Standard 62.2-2022, Ventilation and Acceptable Indoor Air Quality in Residential Buildings (fact sheet) or ANSI/ASHRAE Standard 62.1-2022, Ventilation and Acceptable Indoor Air Quality (fact sheet). Build: flues, gas and fan wiring by qualified people. Deploy: check pollutant levels against WHO global air quality guidelines: particulate matter (PM2.5 and PM10), ozone, nitrogen dioxide, sulfur dioxide and carbon monoxide; keep filters and fans maintained, which 62.1 makes part of compliance ANSI/ASHRAE Standard 62.1-2022, Ventilation and Acceptable Indoor Air Quality (fact sheet).
Resources at each stage
1 Learn
Understand
- Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80) Framework, S0
- WHO global air quality guidelines: particulate matter (PM2.5 and PM10), ozone, nitrogen dioxide, sulfur dioxide and carbon monoxide Standard, S1
- Household air pollution (WHO fact sheet) Guide, S2
- WHO Guidelines for indoor air quality: Household fuel combustion Guide, S2
- Roadmap to improve and ensure good indoor ventilation in the context of COVID-19 Guide, S1
2 Design
Size and choose
- ANSI/ASHRAE Standard 62.1-2022, Ventilation and Acceptable Indoor Air Quality (fact sheet) Standard, S1
- ANSI/ASHRAE Standard 62.2-2022, Ventilation and Acceptable Indoor Air Quality in Residential Buildings (fact sheet) Standard, S1
- Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80) Framework, S0
- WHO global air quality guidelines: particulate matter (PM2.5 and PM10), ozone, nitrogen dioxide, sulfur dioxide and carbon monoxide Standard, S1
- WHO Guidelines for indoor air quality: Household fuel combustion Guide, S2
- Roadmap to improve and ensure good indoor ventilation in the context of COVID-19 Guide, S1
4 Deploy
Install, run and measure
- ANSI/ASHRAE Standard 62.1-2022, Ventilation and Acceptable Indoor Air Quality (fact sheet) Standard, S1
- ANSI/ASHRAE Standard 62.2-2022, Ventilation and Acceptable Indoor Air Quality in Residential Buildings (fact sheet) Standard, S1
- Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80) Framework, S0
- Roadmap to improve and ensure good indoor ventilation in the context of COVID-19 Guide, S1
What changes between 30 adults and 300 people
For 30 adults, a shared kitchen and common rooms dominate: one well-ventilated, clean-fuel kitchen protects everyone. For 300 people household kitchens and heaters multiply the sources, so the fuel choice for every home matters more than any single ventilation system; WHO estimates 2.9 million premature deaths from household air pollution in 2021 Household air pollution (WHO fact sheet).
Reference designs
Open for contributions Designs with drawings, specifications and a bill of materials. Add to it
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
Depends on, and completes
It is one of 22 elements that complete Shelter and construction.
The standing questions
Who pays for clean stoves and fans. Who cleans filters and checks flues. Who decides what may be burned indoors.
Environments
Arctic cold. No source with measured results for ventilation or heat recovery in arctic buildings was opened. Hot deserts and humid tropics. Annex 80 treats humidity removal and ventilative cooling as separate tasks Resilient Cooling of Buildings: Project Summary Report (IEA EBC Annex 80). Rural settings everywhere. WHO reports 49% of rural residents cooked with polluting fuels in 2021, against 14% in towns Household air pollution (WHO fact sheet). Islands, high altitude, flood plains. No source found.
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.