The element
- Requirement
Every structure sits on a foundation designed for the ground beneath it, every retaining wall holds the earth and water behind it, and every trench is dug, supported and backfilled so that no one is buried and no buried service is struck.
- How to tell
- The ground is investigated before foundations are designed. In Europe, EN 1997 applies to the geotechnical aspects of design, including earth pressures and groundwater, with a second part on ground investigation and testing (EN 1997 Eurocode 7: Geotechnical design). In seismic regions, EN 1998-5 covers foundations, retaining structures and geotechnical aspects (EN 1998 Eurocode 8: Design of structures for earthquake resistance).
- Light structures need foundations too: the greenhouse standard covers the structure "including their foundations" (EN 13031-1:2019 Greenhouses - Design and construction - Part 1: Commercial production greenhouses).
- Before digging, buried services are located. United States rules require estimated utility locations to be determined before an excavation is opened (29 CFR 1926.651 Specific excavation requirements).
- Trenches are protected. The same rules require a protective system against cave-in for every worker in an excavation, except under 5 feet (1.52 m) deep where a competent person finds no sign of potential cave-in; systems outside the tabulated options need approval by a registered professional engineer (29 CFR 1926.652 Requirements for protective systems). Spoil and equipment stay at least 2 feet from the edge, trenches 4 feet deep or more have a way out within 25 feet of travel, and a competent person inspects daily and after rain (29 CFR 1926.651 Specific excavation requirements).
- Site safety follows the ILO code of practice for construction (Safety and health in construction (Revised edition)).
- These figures are examples of what one country's rules state; national rules govern.
- Options
Strip and pad footings. Common for small buildings on firm ground; sized by the engineer from the ground investigation (EN 1997 Eurocode 7: Geotechnical design). Raft foundations. Spread load on weaker ground. Piles and ground screws. For soft ground or light structures; Eurocode 3 has a part on steel piling (eurocode-3-steel-jrc is the steel reference). Retaining walls. Gravity, reinforced or anchored; designed for earth and water pressure (EN 1997 Eurocode 7: Geotechnical design), and for earthquake where it applies (EN 1998 Eurocode 8: Design of structures for earthquake resistance). Shared service trenches. Water, drainage, power and data laid together where rules on separation allow, recorded as built.
- Settled, open, contested
Settled: protection against cave-in, safe exits and inspection are required by rule (29 CFR 1926.652 Requirements for protective systems, 29 CFR 1926.651 Specific excavation requirements). Open: this work found no open, citable guide to choosing foundation types by soil; that choice stays with the engineer and the ground investigation. Contested: shared or separate trenches. Shared corridors save digging and keep records together; separation reduces the risk of damage to one service while working on another. National rules set minimum separations.
The four stages
- Learn: the ground and its hazards (EN 1997 Eurocode 7: Geotechnical design, GEM Global Seismic Hazard Map).
- Design: by the engineer from the investigation (EN 1997 Eurocode 7: Geotechnical design, EN 1998 Eurocode 8: Design of structures for earthquake resistance).
- Build: locate services, protect trenches, inspect daily (29 CFR 1926.651 Specific excavation requirements, 29 CFR 1926.652 Requirements for protective systems, Safety and health in construction (Revised edition)).
- Deploy: as-built drawings of every buried service; watch retaining walls for movement and blocked drainage.
Resources at each stage
1 Learn
Understand
- EN 1993 Eurocode 3: Design of steel structures Standard, S3
- EN 1997 Eurocode 7: Geotechnical design Standard, S3
- EN 1998 Eurocode 8: Design of structures for earthquake resistance Standard, S3
- GEM Global Seismic Hazard Map Dataset, S2
- Safety and health in construction (Revised edition) Standard, S3
2 Design
Size and choose
- EN 13031-1:2019 Greenhouses - Design and construction - Part 1: Commercial production greenhouses Standard, S3
- EN 1993 Eurocode 3: Design of steel structures Standard, S3
- EN 1997 Eurocode 7: Geotechnical design Standard, S3
- EN 1998 Eurocode 8: Design of structures for earthquake resistance Standard, S3
- GEM Global Seismic Hazard Map Dataset, S2
- Safety and health in construction (Revised edition) Standard, S3
3 Build
Build or obtain
- Safety and health in construction (Revised edition) Standard, S3
- 29 CFR 1926.651 Specific excavation requirements Standard, S3
- 29 CFR 1926.652 Requirements for protective systems Standard, S3
What changes between 30 adults and 300 people
At 30 adults, foundations are for a few buildings and the trenches are short, but a single collapse can kill; the group hires a machine and an operator and follows the trench rules. At 300 people, a ground investigation for the whole site, a service corridor plan, a contractor for deep excavations and a drawing register of all buried services are needed.
Reference designs
Open for contributions Designs with drawings, specifications and a bill of materials. Add to it
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
| Resource | Type | Origin | Maturity | Safety | Licence, as stated at its source |
|---|---|---|---|---|---|
| EN 13031-1:2019 Greenhouses - Design and construction - Part 1: Commercial production greenhouses | Standard | External | Established | S3 | Not stated on the page opened |
| EN 1993 Eurocode 3: Design of steel structures | Standard | External | Established | S3 | Not stated on the page opened |
| EN 1997 Eurocode 7: Geotechnical design | Standard | External | Established | S3 | Not stated on the page opened |
| EN 1998 Eurocode 8: Design of structures for earthquake resistance | Standard | External | Established | S3 | Not stated on the page opened |
| GEM Global Seismic Hazard Map | Dataset | External | Established | S2 | CC BY-NC-SA 4.0 for downloads and viewer; CC BY-SA 4.0 for the PDF poster and PNG |
| Safety and health in construction (Revised edition) | Standard | External | Established | S3 | Not stated on the page opened |
| 29 CFR 1926.651 Specific excavation requirements | Standard | External | Established | S3 | Not stated on the page opened |
| 29 CFR 1926.652 Requirements for protective systems | Standard | External | Established | S3 | Not stated on the page opened |
Depends on, and completes
It is one of 22 elements that complete Shelter and construction.
The standing questions
Who pays for the ground investigation. Who keeps the drawings of buried services. Who has the authority to stop a dig.
Environments
foundations and retaining structures under EN 1998-5 (EN 1998 Eurocode 8: Design of structures for earthquake resistance); hazard from the global map where no national map exists (GEM Global Seismic Hazard Map).
groundwater pressure is part of geotechnical design (EN 1997 Eurocode 7: Geotechnical design).
- Arctic cold, hot deserts, islands and coasts, tropical humid forest, temperate forest, high altitude: no source found in this work for foundation practice specific to these settings, including permafrost.
Environment profiles for these settings: Seismic zones; River deltas and flood plains. All environments
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.