The element
- Requirement
Free-standing and exposed structures (masts, towers, elevated water tanks, greenhouse frames, solar and antenna mounts, sheds) stand up to the wind, ice, snow and earthquake of their site, are designed by a qualified engineer to the code in force, and can be climbed and maintained safely.
- How to tell
- The structure type has a design code. Eurocode 3 has parts for towers and masts (EN 1993-3-1), chimneys, silos, tanks and pipelines (EN 1993 Eurocode 3: Design of steel structures). Actions in silos and tanks are in EN 1991-4 (EN 1991 Eurocode 1: Actions on structures). Eurocode 8 has parts for silos, tanks and pipelines and for towers, masts and chimneys (EN 1998 Eurocode 8: Design of structures for earthquake resistance).
- Wind and snow come from EN 1991-1-4 and 1-3 or the national equivalent (EN 1991 Eurocode 1: Actions on structures). Where ice forms, ISO 12494 gives the principles for ice mass and for wind on the iced structure, and states that ice can increase wind action considerably (ISO 12494:2017 Atmospheric icing of structures).
- Commercial greenhouse frames and their foundations are designed to EN 13031-1, which does not cover fire (EN 13031-1:2019 Greenhouses - Design and construction - Part 1: Commercial production greenhouses).
- Corrosion protection matches the site class (Categorising corrosivity by type of environment).
- Climbing access has fall protection to the rule in force (29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practices).
- This page gives no wind, ice or load values; they come from the code of the place.
- Options
Lattice steel mast or tower. Radio, wind measurement, lighting; designed to the towers and masts part (EN 1993 Eurocode 3: Design of steel structures). Guyed mast. Light, needs ground space for anchors; Eurocode 3 has a part on structures with tension components (EN 1993 Eurocode 3: Design of steel structures). Elevated water tank. Steel, concrete or plastic on a stand; tank and seismic parts apply (EN 1991 Eurocode 1: Actions on structures, EN 1998 Eurocode 8: Design of structures for earthquake resistance). Greenhouse frame. Steel or aluminium to EN 13031-1 for commercial production houses (EN 13031-1:2019 Greenhouses - Design and construction - Part 1: Commercial production greenhouses, EN 1999 Eurocode 9: Design of aluminium structures). Solar mounting. Ground or roof frames in steel or aluminium; this work found no open structural standard for them, so they are designed for wind and snow to the general actions code.
- Settled, open, contested
Settled: towers, masts and tanks have their own code parts; ice and wind interact (EN 1993 Eurocode 3: Design of steel structures, ISO 12494:2017 Atmospheric icing of structures). Open: solar mounting structures; no open design standard was found in this work. Contested: buy certified or build. Certified products come with design and warranty; locally built frames cost less and can be repaired locally, and need an engineer's check for wind.
The four stages
- Learn: which code parts apply (EN 1993 Eurocode 3: Design of steel structures, EN 1991 Eurocode 1: Actions on structures).
- Design: wind, snow, ice and seismic actions (ISO 12494:2017 Atmospheric icing of structures, EN 1998 Eurocode 8: Design of structures for earthquake resistance); greenhouses (EN 13031-1:2019 Greenhouses - Design and construction - Part 1: Commercial production greenhouses).
- Build: foundations and anchors as designed; corrosion protection (Categorising corrosivity by type of environment).
- Deploy: inspect guys, bolts, anchors and coatings, and after every severe storm; climb only with fall protection (29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practices).
Resources at each stage
1 Learn
Understand
- EN 1991 Eurocode 1: Actions on structures Standard, S3
- EN 1993 Eurocode 3: Design of steel structures Standard, S3
- EN 1998 Eurocode 8: Design of structures for earthquake resistance Standard, S3
- EN 1999 Eurocode 9: Design of aluminium structures Standard, S3
- Categorising corrosivity by type of environment Guide, S0
2 Design
Size and choose
- EN 13031-1:2019 Greenhouses - Design and construction - Part 1: Commercial production greenhouses Standard, S3
- EN 1991 Eurocode 1: Actions on structures Standard, S3
- EN 1993 Eurocode 3: Design of steel structures Standard, S3
- EN 1998 Eurocode 8: Design of structures for earthquake resistance Standard, S3
- EN 1999 Eurocode 9: Design of aluminium structures Standard, S3
- Categorising corrosivity by type of environment Guide, S0
- ISO 12494:2017 Atmospheric icing of structures Standard, S3
- 29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practices Standard, S3
3 Build
Build or obtain
What changes between 30 adults and 300 people
At 30 adults, typical structures are a small antenna mast, a water tank stand, a few solar frames and a greenhouse; each is light but exposed, and a bought, certified product is often the safer path. At 300 people, a communications tower, an elevated storage tank and large solar arrays are civil works with engineered design, permits and a maintenance contract.
Reference designs
Open for contributions Designs with drawings, specifications and a bill of materials. Add to it
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
| Resource | Type | Origin | Maturity | Safety | Licence, as stated at its source |
|---|---|---|---|---|---|
| EN 13031-1:2019 Greenhouses - Design and construction - Part 1: Commercial production greenhouses | Standard | External | Established | S3 | Not stated on the page opened |
| EN 1991 Eurocode 1: Actions on structures | Standard | External | Established | S3 | Not stated on the page opened |
| EN 1993 Eurocode 3: Design of steel structures | Standard | External | Established | S3 | Not stated on the page opened |
| EN 1998 Eurocode 8: Design of structures for earthquake resistance | Standard | External | Established | S3 | Not stated on the page opened |
| EN 1999 Eurocode 9: Design of aluminium structures | Standard | External | Established | S3 | Not stated on the page opened |
| Categorising corrosivity by type of environment | Guide | External | Established | S0 | Not stated on the page opened |
| ISO 12494:2017 Atmospheric icing of structures | Standard | External | Established | S3 | Not stated on the page opened |
| 29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practices | Standard | External | Established | S3 | Not stated on the page opened |
Depends on, and completes
Depends on 6.2.
It is one of 22 elements that complete Shelter and construction.
The standing questions
Who climbs, and with what training. Who inspects after a storm. Who decides when a mast comes down.
Environments
ice mass and wind on iced structures (ISO 12494:2017 Atmospheric icing of structures); snow loads (EN 1991 Eurocode 1: Actions on structures).
very high corrosivity, C5 at the coast and CX offshore (Categorising corrosivity by type of environment).
tanks and towers have seismic parts (EN 1998 Eurocode 8: Design of structures for earthquake resistance).
- Hot deserts, tropical humid forest, temperate forest, flood plains: no source found specific to these structures.
Environment profiles for these settings: Arctic, subarctic and permafrost, including sea ice; Extreme cold; Mountains and high altitude; Small islands and coasts; Seismic zones. All environments
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.