Requirement

Free-standing and exposed structures (masts, towers, elevated water tanks, greenhouse frames, solar and antenna mounts, sheds) stand up to the wind, ice, snow and earthquake of their site, are designed by a qualified engineer to the code in force, and can be climbed and maintained safely.

How to tell
Options

Lattice steel mast or tower. Radio, wind measurement, lighting; designed to the towers and masts part (EN 1993 Eurocode 3: Design of steel structures). Guyed mast. Light, needs ground space for anchors; Eurocode 3 has a part on structures with tension components (EN 1993 Eurocode 3: Design of steel structures). Elevated water tank. Steel, concrete or plastic on a stand; tank and seismic parts apply (EN 1991 Eurocode 1: Actions on structures, EN 1998 Eurocode 8: Design of structures for earthquake resistance). Greenhouse frame. Steel or aluminium to EN 13031-1 for commercial production houses (EN 13031-1:2019 Greenhouses - Design and construction - Part 1: Commercial production greenhouses, EN 1999 Eurocode 9: Design of aluminium structures). Solar mounting. Ground or roof frames in steel or aluminium; this work found no open structural standard for them, so they are designed for wind and snow to the general actions code.

Settled, open, contested

Settled: towers, masts and tanks have their own code parts; ice and wind interact (EN 1993 Eurocode 3: Design of steel structures, ISO 12494:2017 Atmospheric icing of structures). Open: solar mounting structures; no open design standard was found in this work. Contested: buy certified or build. Certified products come with design and warranty; locally built frames cost less and can be repaired locally, and need an engineer's check for wind.

The four stages

Resources at each stage

What changes between 30 adults and 300 people

At 30 adults, typical structures are a small antenna mast, a water tank stand, a few solar frames and a greenhouse; each is light but exposed, and a bought, certified product is often the safer path. At 300 people, a communications tower, an elevated storage tank and large solar arrays are civil works with engineered design, permits and a maintenance contract.

Reference designs

Open for contributions Designs with drawings, specifications and a bill of materials. Add to it

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
EN 13031-1:2019 Greenhouses - Design and construction - Part 1: Commercial production greenhousesStandardExternalEstablishedS3Not stated on the page opened
EN 1991 Eurocode 1: Actions on structuresStandardExternalEstablishedS3Not stated on the page opened
EN 1993 Eurocode 3: Design of steel structuresStandardExternalEstablishedS3Not stated on the page opened
EN 1998 Eurocode 8: Design of structures for earthquake resistanceStandardExternalEstablishedS3Not stated on the page opened
EN 1999 Eurocode 9: Design of aluminium structuresStandardExternalEstablishedS3Not stated on the page opened
Categorising corrosivity by type of environmentGuideExternalEstablishedS0Not stated on the page opened
ISO 12494:2017 Atmospheric icing of structuresStandardExternalEstablishedS3Not stated on the page opened
29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practicesStandardExternalEstablishedS3Not stated on the page opened

Depends on, and completes

Depends on 6.2.

It is one of 22 elements that complete Shelter and construction.

The standing questions

Who climbs, and with what training. Who inspects after a storm. Who decides when a mast comes down.

Environments

Environment profiles for these settings: Arctic, subarctic and permafrost, including sea ice; Extreme cold; Mountains and high altitude; Small islands and coasts; Seismic zones. All environments

Safety

State and evidence

Drafted

An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.

Evidence from a real place or system is recorded here, with what did not work. What the states mean

History