Public Protocol
Platform

Element 9.22

Automating, retrofitting and monitoring machinery

Sheet
9.22
Chapter
9 Manufacturing and repair
State
Drafted
Release
16 November 2026
Editor
Contributed by Praecise as open research
Reviewers
To be named at review
Safety
S3, as the chapter
Licence
CC BY-SA 4.0
Resources
10

The element

Requirement

Old and new machines are given open control, sensors and monitoring so that they can be kept running, repaired and improved by the community; a change to control never removes a safety function; and monitoring data are used to service machines before they fail.

How to tell
  • Machine control runs on open software the community can maintain. LinuxCNC drives mills, lathes, plasma and laser cutters and robot arms (LinuxCNC); grblHAL is CNC firmware for 32-bit microcontrollers with drivers for more than 15 processor families (grblHAL); OpenPLC Runtime runs IEC 61131-3 programs such as ladder logic and structured text on almost any Linux system (OpenPLC Runtime v4).
  • The control program, wiring and settings are documented and backed up.
  • Each machine has a maintenance log, and where monitoring is fitted the measured signal and the alarm threshold are recorded.
  • Safety functions, such as emergency stops, guards and interlocks, are kept or improved after the retrofit, and the machine is inspected before use (Provision and Use of Work Equipment Regulations 1998 (PUWER)). In the European Union, the Machinery Regulation applies from 20 January 2027 and covers cyber-safety of safety control systems (Machinery Regulation (EU) 2023/1230).
Options
Settled, open, contested

Settled: open machine control and open PLC software are in use (LinuxCNC, OpenPLC Runtime v4). Settled: fault detection from machine sound trained only on normal sounds is an active, benchmarked field (DCASE 2024 Task 2: First-shot unsupervised anomalous sound detection for machine condition monitoring). Open: whether models trained on laboratory datasets transfer to one community's own machines; most published data are from test rigs or simulation (NASA PCoE Data Set Repository). Contested: rule-based alarms or learned models. Thresholds are simple and explainable; learned models can catch faults no one predicted but raise false alarms. Benchmarks score both detection and false alarms for this reason (DCASE 2024 Task 2: First-shot unsupervised anomalous sound detection for machine condition monitoring).

The four stages

Resources at each stage

What changes between 30 adults and 300 people

At 30 adults, retrofitting one machine, such as a used mill, with open control, and a paper maintenance log, are the right scale. At 300 people, pumps, generators, kilns and workshop machines justify a small monitoring network, a PLC for repeated processes, and a maintenance plan driven by measured condition.

Reference designs

  • Reference design

    Bosch Sensortec BMI270 inertial measurement unit

    Maker's page for a low-power six-axis IMU: accelerometer ranges of 2 to 16 g, gyroscope ranges of 125 to 2,000 degrees per second, 685 microamps at full data rate, -40 to 85 degrees C, SPI and I2C, with on-chip motion, step and gesture recognition.

    External resource. Not made or verified by Public ProtocolMaturity: EstablishedSafety S0CommercialListed 16 November 2026
  • Reference design

    OSHA Robotics: Standards

    US Occupational Safety and Health Administration list of the consensus standards that apply to robots, stated not to be OSHA regulations: ISO 12100, ISO 10218-1 and -2 (adopted in the US as ANSI/RIA R15.06-2012 and in Canada as CSA Z434), ISO/TS 15066 on collaborative robot safety, ISO/TR 20218 on end-effectors and load stations, UL 1740 and the RIA technical reports.

    External resource. Not made or verified by Public ProtocolMaturity: EstablishedSafety S3Open or commercial: not stated by the makerListed 16 November 2026

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
Bosch Sensortec BMI270 inertial measurement unitReference designExternalEstablishedS0Not stated on the page opened
DCASE 2024 Task 2: First-shot unsupervised anomalous sound detection for machine condition monitoringDatasetExternalWorkingS0Not stated on the page opened
Machinery Regulation (EU) 2023/1230StandardExternalEstablishedS3Not stated on the page opened
grblHALRepositoryExternalEstablishedS2Not stated on the page opened (a COPYING file is present)
Provision and Use of Work Equipment Regulations 1998 (PUWER)StandardExternalEstablishedS2Not stated on the page opened
LinuxCNCToolExternalEstablishedS2GNU GPLv2
MIMII Dataset: Sound Dataset for Malfunctioning Industrial Machine Investigation and InspectionDatasetExternalEstablishedS0Not stated on the page opened
NASA PCoE Data Set RepositoryDatasetExternalEstablishedS0Not stated on the page opened
OpenPLC Runtime v4ToolExternalWorkingS2GPLv3, with a commercial licence available
OSHA Robotics: StandardsReference designExternalEstablishedS3Not stated on the page opened

Depends on, and completes

Depends on 9.2, 9.5, 22.6.

It is one of 34 elements that complete Manufacturing and repair.

The standing questions

Who is allowed to change a machine's control program. Who responds to an alarm at night. Who decides a machine is retired.

Environments

No source found on retrofit or monitoring practice specific to islands and coasts, arctic cold, hot deserts, tropical humid forest, temperate forest, high altitude or flood plains. An inertial sensor used for vibration is rated -40 to 85 degrees C (Bosch Sensortec BMI270 inertial measurement unit).

Safety level S3. Machine control and mains wiring can injure or kill. This text states the requirement and names the recognised sources; it is not a procedure. Retrofit under a person competent in machine safety and electrical work.

Safety

State and evidence

Drafted

An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.

Evidence from a real place or system is recorded here, with what did not work. What the states mean

History