The element

Requirement

Reclaimed structural members are used only after their origin, condition and properties have been assessed by a competent person under the guidance that exists for the material, and the engineer accepts them for the new use.

How to tell
Options

Reclaimed steel sections. The best documented route, under the 2024 technical specification (CEN/TS 1090-201:2024 Execution of steel structures and aluminium structures - Reuse of structural steel). Reclaimed timber. Beams and boards, regraded (EN 14081-1:2016+A1:2019 Timber structures - Strength graded structural timber with rectangular cross section - Part 1: General requirements). Reclaimed masonry units. Bricks and stone; this work found no open standard for their structural reassessment. Buying from dealers. Directories of reclaimed material dealers exist in north-west Europe (Opalis). Downcycling. Crushed masonry and concrete as fill where structural reuse is not possible.

Settled, open, contested

Settled: reclaimed steel now has a European technical specification (CEN/TS 1090-201:2024 Execution of steel structures and aluminium structures - Reuse of structural steel). Open: the specification is a technical specification, not yet a full European standard, and its guidance on welds and connections is informative only (CEN/TS 1090-201:2024 Execution of steel structures and aluminium structures - Reuse of structural steel). No equivalent was found for timber or masonry. Contested: reuse against certainty. Reuse saves material and carbon; assessment costs money and leaves residual uncertainty about history and hidden hazards. Both sides agree on identification first.

The four stages

Resources at each stage

What changes between 30 adults and 300 people

At 30 adults, reuse is case by case: a few beams for a shed or workshop, assessed with the engineer. At 300 people, a reclaimed materials yard with a keeper, a standing link with local demolition, and a batch approach to assessment become worthwhile; the steel specification groups and declares properties of reclaimed components (CEN/TS 1090-201:2024 Execution of steel structures and aluminium structures - Reuse of structural steel).

Reference designs

Open for contributions Designs with drawings, specifications and a bill of materials. Add to it

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
CEN/TS 1090-201:2024 Execution of steel structures and aluminium structures - Reuse of structural steelStandardExternalWorkingS3Not stated on the page opened
EN 1090-2:2018+A1:2024 Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structuresStandardExternalEstablishedS3Not stated on the page opened
EN 14081-1:2016+A1:2019 Timber structures - Strength graded structural timber with rectangular cross section - Part 1: General requirementsStandardExternalEstablishedS3Not stated on the page opened
EN 16351:2021 Timber structures - Cross laminated timber - RequirementsStandardExternalEstablishedS3Not stated on the page opened
Chromated Arsenicals (CCA)GuideExternalEstablishedS2Not stated on the page opened
ICE Database (Inventory of Carbon and Energy)DatasetExternalEstablishedS0Educational use only; must not be used for commercial applications
OpalisLibraryExternalWorkingS0CC BY-NC-SA unless stated otherwise

Depends on, and completes

Depends on 11.5, 6.5, 6.2.

It is one of 19 elements that complete Materials and supply.

The standing questions

Who takes responsibility for a reused beam. Who pays for testing. Who decides what is too uncertain to use.

Environments

No source found in this work that ties reuse of structural members to a particular climate. Corrosion and decay of the original service environment are part of the assessment; see the steel and timber elements.