United States workplace regulation for stairs. For standard stairs it sets an angle of 30 to 50 degrees, a riser of at most 9.5 inches (24 cm), a tread of at least 9.5 inches, a width of at least 22 inches, landings at least 30 inches deep, and a capacity of five times the normal anticipated live load and never less than a 1,000 pound concentrated load.
https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.25
- Maintainer
- Occupational Safety and Health Administration, United States
- Licence, as stated at its source
- Not stated on the page opened
- Open or commercial
- Open
- Maturity
- EstablishedOur reading, 16 November 2026
- Safety
- S3fall, legal
- Review
- Listed 16 November 2026by Public Protocol editors
- Checked
- 16 November 2026
- Next check due
- 16 May 2027
- Steward
- Public Protocol editors
Where it sits in the blueprint
- Domains
- Stages
Design, Build
- Elements it supports
- Context
Climate, setting, scale, cost and skill: not stated in this entry. Check the source against your own place and numbers.
Verification
No verification is recorded on Public Platform for this entry. Records are added when someone reads it for accuracy, reviews it with a stated qualification, builds it or measures it.
Record
- How it came in
Seed catalogue, 16 November 2026. Listed from Praecise open research. The source was opened and described on the date shown.
- Licence
Not stated on the page opened. Read at https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.25. How licences are recorded
- Something wrong?