Element 6.20
Railings, stairs, platforms and fall protection
- Sheet
- 6.20
- Chapter
- 6 Shelter and construction
- State
- Drafted
- Release
- 16 November 2026
- Editor
- Contributed by Praecise as open research
- Reviewers
- To be named at review
- Safety
- S3, as the chapter
- Licence
- CC BY-SA 4.0
- Resources
- 8
The element
- Requirement
Every edge people can fall from, every stair and every raised platform or walkway has guarding, rails and dimensions that meet the code in force, and is strong enough for the loads the code states, so that falls are prevented rather than survived.
- How to tell
- The governing rule is identified: a building code for buildings, a machinery standard for access to machines, a workplace rule for workplaces.
- For buildings in England, Approved Document K is the statutory guidance on staircases, ladders, ramps, guarding and vehicle barriers in and around all types of building (Protection from falling, collision and impact: Approved Document K).
- For workplaces in the United States, 29 CFR 1910.29 sets guardrail top-rail height at 42 inches (107 cm) plus or minus 3 inches, top-rail strength of at least 200 pounds (890 N) applied downward or outward, and midrail strength of at least 150 pounds (667 N) (29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practices). Standard stairs are set at 30 to 50 degrees, with a riser of at most 9.5 inches and a tread of at least 9.5 inches, at least 22 inches wide, and must carry five times the normal anticipated live load and never less than a 1,000 pound concentrated load (29 CFR 1910.25 Stairways).
- For stairs, stepladders and guard-rails that are part of a machine, or give access to it within a building, ISO 14122-3 applies (ISO 14122-3:2016 Safety of machinery - Permanent means of access to machinery - Part 3: Stairs, stepladders and guard-rails).
- Ramps and stairs used by everyone meet the accessibility standard too (Access to and use of buildings: Approved Document M, ADA Accessibility Standards).
- The figures above are examples of what codes state; the code of the place governs, and an engineer or building control confirms.
- Options
Fixed guardrails and balustrades. The first choice wherever an edge exists. Stairs in place of ladders. Safer for daily use; ladders where stairs cannot fit. Prefabricated platforms and walkways. Steel, aluminium or composite gratings with rails, bought to a standard. Built in timber. Decks, stairs and rails within the timber code and the guarding rules. Temporary edge protection during building. Under the construction safety code (Safety and health in construction (Revised edition)).
- Settled, open, contested
Settled: guarding height, strength and stair geometry are set in codes; the examples cited show the kind of figures they state (29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practices, 29 CFR 1910.25 Stairways). Open: codes differ country by country, and the values in this page are examples, not universal. The machinery access standard is under revision (ISO 14122-3:2016 Safety of machinery - Permanent means of access to machinery - Part 3: Stairs, stepladders and guard-rails). Contested: open balustrades and climbability. Open designs give light and views; closed or vertical designs prevent children from climbing. Building codes settle this locally.
The four stages
- Learn: what the codes require (Protection from falling, collision and impact: Approved Document K, 29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practices, 29 CFR 1910.25 Stairways).
- Design: dimensions and loads from the code; machinery access (ISO 14122-3:2016 Safety of machinery - Permanent means of access to machinery - Part 3: Stairs, stepladders and guard-rails); accessible routes (Access to and use of buildings: Approved Document M, ADA Accessibility Standards).
- Build: fixings and connections as designed; edge protection while building (Safety and health in construction (Revised edition)).
- Deploy: check rails, fixings and treads on the maintenance schedule (6.7).
Resources at each stage
1 Learn
Understand
- ADA Accessibility Standards Standard, S1
- Access to and use of buildings: Approved Document M Standard, S1
- Safety and health in construction (Revised edition) Standard, S3
2 Design
Size and choose
- ADA Accessibility Standards Standard, S1
- Protection from falling, collision and impact: Approved Document K Standard, S3
- Access to and use of buildings: Approved Document M Standard, S1
- Safety and health in construction (Revised edition) Standard, S3
- ISO 12494:2017 Atmospheric icing of structures Standard, S3
- ISO 14122-3:2016 Safety of machinery - Permanent means of access to machinery - Part 3: Stairs, stepladders and guard-rails Standard, S3
- 29 CFR 1910.25 Stairways Standard, S3
- 29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practices Standard, S3
3 Build
Build or obtain
- Safety and health in construction (Revised edition) Standard, S3
- ISO 14122-3:2016 Safety of machinery - Permanent means of access to machinery - Part 3: Stairs, stepladders and guard-rails Standard, S3
- 29 CFR 1910.25 Stairways Standard, S3
- 29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practices Standard, S3
What changes between 30 adults and 300 people
At 30 adults, the edges are few: stairs, a loft, a deck, a water tank platform. Each is checked against the code. At 300 people, with children, old people and visitors, every shared building, platform, bridge and tank access is guarded to the building code's higher standard, and an annual check is part of maintenance.
Reference designs
Open for contributions Designs with drawings, specifications and a bill of materials. Add to it
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
| Resource | Type | Origin | Maturity | Safety | Licence, as stated at its source |
|---|---|---|---|---|---|
| ADA Accessibility Standards | Standard | External | Established | S1 | Not stated on the page opened |
| Protection from falling, collision and impact: Approved Document K | Standard | External | Established | S3 | Open Government Licence v3.0, except where otherwise stated |
| Access to and use of buildings: Approved Document M | Standard | External | Established | S1 | Open Government Licence v3.0 |
| Safety and health in construction (Revised edition) | Standard | External | Established | S3 | Not stated on the page opened |
| ISO 12494:2017 Atmospheric icing of structures | Standard | External | Established | S3 | Not stated on the page opened |
| ISO 14122-3:2016 Safety of machinery - Permanent means of access to machinery - Part 3: Stairs, stepladders and guard-rails | Standard | External | Established | S3 | Not stated on the page opened |
| 29 CFR 1910.25 Stairways | Standard | External | Established | S3 | Not stated on the page opened |
| 29 CFR 1910.29 Fall protection systems and falling object protection - criteria and practices | Standard | External | Established | S3 | Not stated on the page opened |
Depends on, and completes
It is one of 22 elements that complete Shelter and construction.
The standing questions
Who checks every edge. Who pays to bring old structures up to the code. Who decides when a rail is loose enough to close a stair.
Environments
No source found in this work for how guarding or stair requirements change by climate. Ice and snow on stairs and walkways, and corrosion of rails at the coast, are covered in the loads and steel elements (iso-12494-atmospheric-icing is the icing reference).
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.