Public Protocol
Platform

Element 5.21

Small and medium wind

Sheet
5.21
Chapter
5 Energy
State
Drafted
Release
16 November 2026
Editor
Contributed by Praecise as open research
Reviewers
To be named at review
Safety
S3, as the chapter
Licence
CC BY-SA 4.0
Resources
11

The element

Requirement

Where the community has a proven wind resource, it uses turbines certified to the small-turbine standard or built to an open design under qualified supervision, on towers and foundations engineered for the site, with a plan for safe work at height and for the turbine's whole life.

How to tell

The turbine is certified under IEC 61400-2, which covers turbines with a rotor swept area of 200 m2 or less generating below 1,000 V a.c. or 1,500 V d.c., on or off grid, and sets requirements for design, installation, maintenance and operation, including support structures and foundations (BS EN 61400-2:2014 Wind turbines - Small wind turbines (identical to IEC 61400-2:2013/COR1:2019)). In North America the ICC-SWCC programme certifies small and medium turbines for structural safety, durability, acoustics and power production, with standardised power curves and sound levels; towers and foundations are outside its scope and certifications are renewed each year (ICC-SWCC: Small Wind Certification Council). The resource is checked against the Global Wind Atlas (Global Wind Atlas) and, for an hourly profile, Renewables.ninja (Renewables.ninja), then confirmed by measurement at hub height before purchase.

Options

Certified small turbines. Fit a group without in-house engineering. The certificate states the power curve and sound level, which makes yield and noise predictable (ICC-SWCC: Small Wind Certification Council).

Locally built turbines. Wind Empowerment supports locally manufactured small turbines (Wind Empowerment). They suit groups who want repair skills at home; they do not carry a certificate unless tested.

Medium or distributed wind. Turbines serving on-site or local loads; PNNL publishes an annual data update and a project database (Distributed Wind Energy Technology Data Update (Pacific Northwest National Laboratory)).

Wind in a hybrid. King Island combined wind and solar with storage and control (King Island Renewable Energy Integration Project). Size the mix in a model (MicroGridsPy).

Settled, open, contested

Settled. Certification and engineered foundations. Raising, lowering and climbing a tower is work at height near rotating machinery and live conductors: S3, done by trained people.

Open. How well real yields at low hub heights match predictions. PNNL's tools-assessing-performance work exists to reduce uncertainty in distributed wind production estimates (Distributed Wind Energy Technology Data Update (Pacific Northwest National Laboratory)). No open yield figure was verified in this work.

Contested. Locally built or certified machines: repairability and local skills against tested safety and predictable output.

The four stages

Learn: (Distributed Wind Energy Technology Data Update (Pacific Northwest National Laboratory)) (Wind Empowerment). Design: resource from (Global Wind Atlas) and (Renewables.ninja), measured on site; mix sized with (MicroGridsPy). Build: certified turbine (BS EN 61400-2:2014 Wind turbines - Small wind turbines (identical to IEC 61400-2:2013/COR1:2019)) (ICC-SWCC: Small Wind Certification Council); tower and foundation designed by a structural engineer; electrical work to the IEC 62257 series off grid (IEC TS 62257-100:2022 Renewable energy off-grid systems - Part 100: Overview of the IEC 62257 series). This page gives no erection or climbing procedure. Deploy: log output against the certified power curve (OpenEnergyMonitor).

Resources at each stage

What changes between 30 adults and 300 people

For 30 adults, one turbine beside a solar array can carry winter nights in a windy place. For 300 people, a few larger turbines with an operator and a maintenance contract become possible, and noise and setback from homes must be settled with neighbours.

Reference designs

Open for contributions Designs with drawings, specifications and a bill of materials. Add to it

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
King Island Renewable Energy Integration ProjectCase studyExternalReplicatedS3Not stated on the page opened
Global Wind AtlasDatasetExternalEstablishedS0Creative Commons Attribution 4.0 (stated on the World Bank Data Catalog entry for version 3.0)
ICC-SWCC: Small Wind Certification CouncilStandardExternalEstablishedS0Not stated on the page opened
IEA Wind TCP Task 19: Wind Energy in Cold ClimatesFrameworkExternalEstablishedS3Not stated on the page opened
BS EN 61400-2:2014 Wind turbines - Small wind turbines (identical to IEC 61400-2:2013/COR1:2019)StandardExternalEstablishedS3Not stated on the page opened
IEC TS 62257-100:2022 Renewable energy off-grid systems - Part 100: Overview of the IEC 62257 seriesStandardExternalEstablishedS2Not stated on the page opened
MicroGridsPyToolExternalNot assessedS0European Union Public Licence: the README text cites v1.1 and the repository lists EUPL-1.2
OpenEnergyMonitorToolExternalNot assessedS2Not stated on the pages opened
Distributed Wind Energy Technology Data Update (Pacific Northwest National Laboratory)DatasetExternalEstablishedS0Not stated on the page opened
Renewables.ninjaToolExternalEstablishedS0Creative Commons Attribution-NonCommercial 4.0 International (data); commercial use by arrangement with the operators
Wind EmpowermentLibraryExternalNot assessedS2Not stated on the page opened

Depends on, and completes

Depends on 5.1, 5.2.

It is one of 23 elements that complete Energy.

The standing questions

Who climbs and who is trained to. Who hears the turbine. Who decides where it stands.

Environments

Islands and coasts. King Island in Australia combined wind, solar and biodiesel with batteries and control to supply over 65% of its annual energy from renewables (King Island Renewable Energy Integration Project). The Global Wind Atlas 4.0 extended to offshore economic zones and was validated in the Maldives, among others (Global Wind Atlas).

Arctic cold. IEA Wind Task 19 covers icing and temperatures below standard operating limits, with an ice loss method, ice detection guidelines and ice throw recommendations (IEA Wind TCP Task 19: Wind Energy in Cold Climates). Ice thrown from blades is a hazard to people below.

Hot deserts. No source found.

Tropical humid forest. The atlas was validated for Bangladesh, Papua New Guinea and Vietnam, among others (Global Wind Atlas). No source found on turbine performance.

Temperate forest. The atlas's version 4.0 added a displacement height model built from tree height data, which matters where forest slows the wind (Global Wind Atlas).

High altitude. No source found.

Flood plains. No source found.

Other harsh settings. No source found.

Safety

State and evidence

Drafted

An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.

Evidence from a real place or system is recorded here, with what did not work. What the states mean

History