Element 5.22
Solar photovoltaics for every climate
- Sheet
- 5.22
- Chapter
- 5 Energy
- State
- Drafted
- Release
- 16 November 2026
- Editor
- Contributed by Praecise as open research
- Reviewers
- To be named at review
- Safety
- S3, as the chapter
- Licence
- CC BY-SA 4.0
- Resources
- 21
The element
- Requirement
The community's solar modules, mounting and layout are chosen for its own climate, qualified to the international module standards, sized from public resource data for the exact site, installed by a competent person, and watched year by year for loss of output.
- How to tell
Every module is certified to IEC 61215-1 for design qualification and IEC 61730-1 for safety (IEC 61215-1:2021 Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 1: Test requirements) (IEC 61730-1:2023 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction). IEC 61215-1 states that its test results are not a quantitative prediction of module lifetime (IEC 61215-1:2021 Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 1: Test requirements). IEC 61730-1 covers modules whose 98th-percentile operating temperature is 70 degrees C or less and points to IEC TS 63126 for hotter conditions (IEC 61730-1:2023 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction). Yield is read for the site from the Global Solar Atlas, whose layers are about 250 m and licensed CC BY 4.0 (Global Solar Atlas GIS data (World Bank Data Catalog)), or from PVGIS (PVGIS). Measured output is compared each year with the model. A study of more than 7.2 GW in the United States found an overall loss of 0.75% a year (Photovoltaic fleet degradation insights), and 90% of systems lost less than 2% a year (NREL says long-term degradation of 8 GW of U.S. solar 'matches expectations'): a system losing more than that is among the worst tenth and needs inspection.
- Options
Fixed monofacial arrays. The simplest choice, with no moving parts. Commercial wafer-based modules have risen from about 17% to just under 25% efficiency in ten years, and energy payback is about one year depending on location (Photovoltaics Report).
Bifacial modules and single-axis trackers. Tracking adds 15% to 25% over fixed tilt; bifacial modules on trackers add a further 4% to 15% depending on module type and ground reflectance, 9% on average (Model and Validation of Single-Axis Tracking with Bifacial PV). Trackers add motors and bearings to maintain.
Agrivoltaics. Farming and generation on the same land; Fraunhofer ISE's guideline covers potential, examples and obstacles (Agrivoltaics: Opportunities for Agriculture and the Energy Transition. A Guideline for Germany).
Floating arrays. On reservoirs and ponds. The World Bank names reduced evaporation and higher yield from water cooling, and also a limited track record, water quality, anchoring and maintenance as challenges (Where Sun Meets Water: Floating Solar Market Report).
Building-integrated PV. Modules as roof or facade. IEA PVPS Task 15 states that fire safety and glare still lack clear test methods or thresholds (IEA PVPS Task 15: Enabling Framework for the Development of BIPV).
Tandem and perovskite modules. Laboratory records are 34.85% (certified by NREL) and 35.5% (certified by the EU's ESTI) for perovskite-silicon tandem cells (34.85%! LONGi Breaks World Record for Crystalline Silicon-Perovskite Tandem Solar Cell Efficiency Again) (Longi sets new world record with 35.5%-efficient perovskite-silicon tandem cell); the maker of the latter had no mass-production plan in June 2026. One tandem module entered commercial use in 2024 (20% more powerful tandem solar panels enter commercial use for the first time in the US).
- Settled, open, contested
Settled. Certified modules; yield checked against public data before purchase. Arrays work at hazardous direct-current voltages, and roof work is work at height: S3 where grid-connected or on roofs, done by qualified people.
Open. Perovskite durability. The best outdoor perovskite mini-module in a two-year Cyprus trial kept 78% of its efficiency after one year (EnergyVille/imec and partners show outdoor stability of highly anticipated perovskite solar modules).
Contested. Trackers and bifacial modules for small sites: more energy per module against more parts to maintain.
The four stages
Learn: the state of the market and the technology (Photovoltaics Report) (Snapshot of Global PV Markets 2026) (Best Research-Cell Efficiency Chart). Design: resource and yield from (Global Solar Atlas GIS data (World Bank Data Catalog)) and (PVGIS); detailed modelling with (System Advisor Model (SAM)) or (pvlib python). Build: certified modules (IEC 61215-1:2021 Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 1: Test requirements) (IEC 61730-1:2023 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction); off-grid systems to the IEC 62257 series (IEC TS 62257-100:2022 Renewable energy off-grid systems - Part 100: Overview of the IEC 62257 series), designed and signed off by a qualified electrician; this page gives no installation procedure. Deploy: log output (OpenEnergyMonitor) and compare yearly loss with the fleet figures (Photovoltaic fleet degradation insights).
Resources at each stage
1 Learn
Understand
- Agrivoltaics: Opportunities for Agriculture and the Energy Transition. A Guideline for Germany Guide, S0
- Photovoltaics Report Reference design, S0
- Snapshot of Global PV Markets 2026 Reference design, S0
- IEA PVPS Task 15: Enabling Framework for the Development of BIPV Framework, S2
- EnergyVille/imec and partners show outdoor stability of highly anticipated perovskite solar modules Case study, S0
- 34.85%! LONGi Breaks World Record for Crystalline Silicon-Perovskite Tandem Solar Cell Efficiency Again Case study, S0
- Best Research-Cell Efficiency Chart Dataset, S0
- 20% more powerful tandem solar panels enter commercial use for the first time in the US Case study, S0
- Longi sets new world record with 35.5%-efficient perovskite-silicon tandem cell Case study, S0
- Where Sun Meets Water: Floating Solar Market Report Guide, S0
2 Design
Size and choose
- Model and Validation of Single-Axis Tracking with Bifacial PV Paper, S0
- Agrivoltaics: Opportunities for Agriculture and the Energy Transition. A Guideline for Germany Guide, S0
- Global Solar Atlas GIS data (World Bank Data Catalog) Dataset, S0
- IEA PVPS Task 15: Enabling Framework for the Development of BIPV Framework, S2
- IEC 61215-1:2021 Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 1: Test requirements Standard, S2
- IEC 61730-1:2023 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction Standard, S2
- IEC TS 62257-100:2022 Renewable energy off-grid systems - Part 100: Overview of the IEC 62257 series Standard, S2
- Photovoltaic fleet degradation insights Paper, S0
- System Advisor Model (SAM) Tool, S0
- NREL says long-term degradation of 8 GW of U.S. solar 'matches expectations' Case study, S0
- PVGIS Tool, S0
- pvlib python Library, S0
- Where Sun Meets Water: Floating Solar Market Report Guide, S0
3 Build
Build or obtain
- IEC 61215-1:2021 Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 1: Test requirements Standard, S2
- IEC 61730-1:2023 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction Standard, S2
- IEC TS 62257-100:2022 Renewable energy off-grid systems - Part 100: Overview of the IEC 62257 series Standard, S2
- OpenEnergyMonitor Tool, S2
4 Deploy
Install, run and measure
- Photovoltaic fleet degradation insights Paper, S0
- OpenEnergyMonitor Tool, S2
- NREL says long-term degradation of 8 GW of U.S. solar 'matches expectations' Case study, S0
- pvlib python Library, S0
What changes between 30 adults and 300 people
For 30 adults, fixed roof or ground arrays keep maintenance to cleaning and inspection. For 300 people, a ground array large enough to justify trackers, agrivoltaics on shared land or a floating array on a reservoir becomes worth comparing in a model, and needs a named maintainer.
Reference designs
-
Reference design
A regularly updated slide report on the photovoltaic market and technology, here in the version of 14 July 2026. Its page states that commercial wafer-based module efficiency rose from about 17% to just under 25% in ten years, records lab cells at 27.9% (mono-silicon), 26.9% (perovskite) and 47.6% (concentrator), an energy payback time of about one year depending on location, a price fall of about 26.7% for each doubling of cumulative production, and a typical cost of about 4 euro cents per kWh for large plants.
External resource. Not made or verified by Public ProtocolMaturity: EstablishedSafety S0Open or commercial: not stated by the makerListed 16 November 2026 -
Reference design
Snapshot of Global PV Markets 2026
IEA PVPS Task 1 report of April 2026. Its page estimates 698 GW of PV installed worldwide in 2025, cumulative capacity of nearly 3 TW, PV supplying more than 10% of global electricity demand, and nearly 40 countries installing at least 1 GW each.
External resource. Not made or verified by Public ProtocolMaturity: EstablishedSafety S0Listed 16 November 2026
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
| Resource | Type | Origin | Maturity | Safety | Licence, as stated at its source |
|---|---|---|---|---|---|
| Model and Validation of Single-Axis Tracking with Bifacial PV | Paper | External | Established | S0 | Not stated on the page opened |
| Agrivoltaics: Opportunities for Agriculture and the Energy Transition. A Guideline for Germany | Guide | External | Established | S0 | Not stated on the page opened |
| Photovoltaics Report | Reference design | External | Established | S0 | Not stated on the page opened |
| Global Solar Atlas GIS data (World Bank Data Catalog) | Dataset | External | Established | S0 | Creative Commons Attribution 4.0 |
| Snapshot of Global PV Markets 2026 | Reference design | External | Established | S0 | Not stated on the page opened |
| IEA PVPS Task 15: Enabling Framework for the Development of BIPV | Framework | External | Working | S2 | Not stated on the page opened |
| IEC 61215-1:2021 Terrestrial photovoltaic (PV) modules - Design qualification and type approval - Part 1: Test requirements | Standard | External | Established | S2 | Not stated on the page opened |
| IEC 61730-1:2023 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction | Standard | External | Established | S2 | Not stated on the page opened |
| IEC TS 62257-100:2022 Renewable energy off-grid systems - Part 100: Overview of the IEC 62257 series | Standard | External | Established | S2 | Not stated on the page opened |
| EnergyVille/imec and partners show outdoor stability of highly anticipated perovskite solar modules | Case study | External | Prototype | S0 | Not stated on the page opened |
| Photovoltaic fleet degradation insights | Paper | External | Established | S0 | Not stated on the page opened |
| 34.85%! LONGi Breaks World Record for Crystalline Silicon-Perovskite Tandem Solar Cell Efficiency Again | Case study | External | Prototype | S0 | Not stated on the page opened |
| Best Research-Cell Efficiency Chart | Dataset | External | Established | S0 | The plot is not copyrighted and may be used in presentations and publications, with a notation that states: "This plot is courtesy of the National Laboratory of the Rockies, Golden, CO." |
| System Advisor Model (SAM) | Tool | External | Established | S0 | BSD-3-Clause (the bundled Sandia stepwise and LHS libraries are under LGPL) |
| OpenEnergyMonitor | Tool | External | Not assessed | S2 | Not stated on the pages opened |
| 20% more powerful tandem solar panels enter commercial use for the first time in the US | Case study | External | Not assessed | S0 | Not stated on the page opened |
| Longi sets new world record with 35.5%-efficient perovskite-silicon tandem cell | Case study | External | Prototype | S0 | Not stated on the page opened |
| NREL says long-term degradation of 8 GW of U.S. solar 'matches expectations' | Case study | External | Established | S0 | Not stated on the page opened |
| PVGIS | Tool | External | Established | S0 | Not stated on the tool page opened |
| pvlib python | Library | External | Established | S0 | BSD 3-clause |
| Where Sun Meets Water: Floating Solar Market Report | Guide | External | Established | S0 | Not stated on the page opened |
The standing questions
Who pays for modules certified to the standards. Who inspects and cleans. Who decides between roofs, fields and water.
Environments
Islands and coasts. Floating arrays suit reservoirs where land is scarce (Where Sun Meets Water: Floating Solar Market Report). For salt air, no open field source was opened in this work.
Arctic cold. Cooler climates showed a median loss of 0.48% a year (Photovoltaic fleet degradation insights); snow deeper than 1 m accelerated degradation (NREL says long-term degradation of 8 GW of U.S. solar 'matches expectations').
Hot deserts. Hotter climates showed a median loss of 0.88% a year (Photovoltaic fleet degradation insights); above a 70 degrees C 98th-percentile module temperature, IEC TS 63126 applies (IEC 61730-1:2023 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction). No open source with soiling figures was opened.
Tropical humid forest. No source found.
Temperate forest. No source found.
High altitude. No source found.
Flood plains. In the US fleet, the longest outages after extreme events came mostly from flooding and rain (NREL says long-term degradation of 8 GW of U.S. solar 'matches expectations').
Other harsh settings. Hail over 25 mm and winds over 90 km/h accelerated degradation (NREL says long-term degradation of 8 GW of U.S. solar 'matches expectations').
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.