The element
- Requirement
Metal and fibre-composite structures are designed to the code in force, made from material delivered to its product standard, fabricated and erected to a stated execution standard, and protected against corrosion for the environment where they stand.
- How to tell
- The design code is named. Eurocode 3 covers steel, with parts for joints, fatigue, cold-formed members, stainless steel, bridges, towers and masts, tanks and piling (EN 1993 Eurocode 3: Design of steel structures). Eurocode 9 covers aluminium, including fire, fatigue and cold-formed sheeting (EN 1999 Eurocode 9: Design of aluminium structures).
- The steel is delivered to a product standard, such as EN 10025-2 for hot-rolled non-alloy structural steels, which excludes hollow sections (EN 10025-2:2019 Hot rolled products of structural steels - Part 2: Technical delivery conditions for non-alloy structural steels), with its certificate kept.
- Fabrication and erection follow an execution standard. EN 1090-2 applies to steelwork designed to EN 1993 and differentiates its requirements by execution class (EN 1090-2:2018+A1:2024 Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structures).
- The corrosivity of the site is classed under ISO 12944-2, from C1 indoors to C5 and CX offshore (Categorising corrosivity by type of environment), and the protective system chosen for it, by paint to the ISO 12944 series (ISO 12944-1:2017 Paints and varnishes - Corrosion protection of steel structures by protective paint systems - Part 1: General introduction) or hot-dip galvanizing to ISO 1461 (ISO 1461:2022 Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods).
- Fibre-polymer composite structures are designed to CEN/TS 19101, which covers resistance, serviceability, durability and fire resistance and excludes composite cables (CEN/TS 19101:2022 Design of fibre-polymer composite structures).
- Welding fume is controlled (Health risks from welding, and Change in enforcement expectations for mild steel welding fume).
- Options
Hot-rolled steel frame. Workshops, halls, wide spans (EN 1993 Eurocode 3: Design of steel structures). Cold-formed light steel. Sheds, frames and racks; covered by its own Eurocode 3 part (EN 1993 Eurocode 3: Design of steel structures). Stainless steel. For aggressive exposure; its own Eurocode 3 part (EN 1993 Eurocode 3: Design of steel structures). Aluminium. Light frames, walkways and mounting structures (EN 1999 Eurocode 9: Design of aluminium structures). Fibre-reinforced polymer. Corrosion-resistant footbridges, gratings and frames; European guidance grew from a Joint Research Centre report of 2016 into the 2022 technical specification (Prospect for New Guidance in the Design of FRP, CEN/TS 19101:2022 Design of fibre-polymer composite structures).
- Settled, open, contested
Settled: corrosion protection is chosen by environment class (Categorising corrosivity by type of environment); steelwork execution has its own standard (EN 1090-2:2018+A1:2024 Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structures). Open: composites. The technical specification of 2022 is being revised into draft European standards (CEN/TS 19101:2022 Design of fibre-polymer composite structures); long-term field data is thinner than for steel. Contested: galvanizing against paint. Both have standards; the choice depends on exposure, size of parts, the galvanizing bath within reach, and maintenance access.
The four stages
- Learn: the code parts (EN 1993 Eurocode 3: Design of steel structures, EN 1999 Eurocode 9: Design of aluminium structures); composites (Prospect for New Guidance in the Design of FRP).
- Design: by the engineer to the code; corrosion class from the site (Categorising corrosivity by type of environment).
- Build: certified material (EN 10025-2:2019 Hot rolled products of structural steels - Part 2: Technical delivery conditions for non-alloy structural steels); execution (EN 1090-2:2018+A1:2024 Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structures); coating (ISO 1461:2022 Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods, ISO 12944-1:2017 Paints and varnishes - Corrosion protection of steel structures by protective paint systems - Part 1: General introduction); fume control (Health risks from welding, and Change in enforcement expectations for mild steel welding fume).
- Deploy: inspect coatings and connections on a schedule set by exposure (ISO 12944-1:2017 Paints and varnishes - Corrosion protection of steel structures by protective paint systems - Part 1: General introduction).
Resources at each stage
1 Learn
Understand
- EN 1993 Eurocode 3: Design of steel structures Standard, S3
- EN 1999 Eurocode 9: Design of aluminium structures Standard, S3
- Health risks from welding, and Change in enforcement expectations for mild steel welding fume Guide, S2
- Categorising corrosivity by type of environment Guide, S0
- Prospect for New Guidance in the Design of FRP Paper, S3
2 Design
Size and choose
- CEN/TS 19101:2022 Design of fibre-polymer composite structures Standard, S3
- EN 1993 Eurocode 3: Design of steel structures Standard, S3
- EN 1999 Eurocode 9: Design of aluminium structures Standard, S3
- Categorising corrosivity by type of environment Guide, S0
- ISO 12944-1:2017 Paints and varnishes - Corrosion protection of steel structures by protective paint systems - Part 1: General introduction Standard, S1
- ISO 1461:2022 Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods Standard, S1
3 Build
Build or obtain
- EN 10025-2:2019 Hot rolled products of structural steels - Part 2: Technical delivery conditions for non-alloy structural steels Standard, S2
- EN 1090-2:2018+A1:2024 Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structures Standard, S3
- ISO 1461:2022 Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods Standard, S1
What changes between 30 adults and 300 people
At 30 adults, steel arrives as fabricated, galvanized parts bolted on site, or as light frames; welding on site is limited and done by qualified welders. At 300 people, a fabrication workshop working to an execution standard, a coating contract and an inspection schedule for many structures become worthwhile.
Reference designs
Open for contributions Designs with drawings, specifications and a bill of materials. Add to it
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
Depends on, and completes
It is one of 22 elements that complete Shelter and construction.
The standing questions
Who certifies welders and welds. Who repaints, and when. Who decides to replace a corroded member.
Environments
C5, very high corrosivity such as a coastal refinery; CX offshore; Im4 for immersed assets with cathodic protection (Categorising corrosivity by type of environment).
Eurocode 3 has a part on material toughness and through-thickness properties (EN 1993 Eurocode 3: Design of steel structures); this work found no open source tying steel choice to a climate.
- Hot deserts, tropical humid forest, temperate forest, high altitude, flood plains: no source found specific to metal structures in this work beyond corrosivity classes.
Environment profiles for these settings: Small islands and coasts; Arctic, subarctic and permafrost, including sea ice; Extreme cold. All environments
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.