Public Protocol
Platform

Element 6.21

Steel, aluminium and composite structures

Sheet
6.21
Chapter
6 Shelter and construction
State
Drafted
Release
16 November 2026
Editor
Contributed by Praecise as open research
Reviewers
To be named at review
Safety
S3, as the chapter
Licence
CC BY-SA 4.0
Resources
10

The element

Requirement

Metal and fibre-composite structures are designed to the code in force, made from material delivered to its product standard, fabricated and erected to a stated execution standard, and protected against corrosion for the environment where they stand.

How to tell
Options

Hot-rolled steel frame. Workshops, halls, wide spans (EN 1993 Eurocode 3: Design of steel structures). Cold-formed light steel. Sheds, frames and racks; covered by its own Eurocode 3 part (EN 1993 Eurocode 3: Design of steel structures). Stainless steel. For aggressive exposure; its own Eurocode 3 part (EN 1993 Eurocode 3: Design of steel structures). Aluminium. Light frames, walkways and mounting structures (EN 1999 Eurocode 9: Design of aluminium structures). Fibre-reinforced polymer. Corrosion-resistant footbridges, gratings and frames; European guidance grew from a Joint Research Centre report of 2016 into the 2022 technical specification (Prospect for New Guidance in the Design of FRP, CEN/TS 19101:2022 Design of fibre-polymer composite structures).

Settled, open, contested

Settled: corrosion protection is chosen by environment class (Categorising corrosivity by type of environment); steelwork execution has its own standard (EN 1090-2:2018+A1:2024 Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structures). Open: composites. The technical specification of 2022 is being revised into draft European standards (CEN/TS 19101:2022 Design of fibre-polymer composite structures); long-term field data is thinner than for steel. Contested: galvanizing against paint. Both have standards; the choice depends on exposure, size of parts, the galvanizing bath within reach, and maintenance access.

The four stages

Resources at each stage

What changes between 30 adults and 300 people

At 30 adults, steel arrives as fabricated, galvanized parts bolted on site, or as light frames; welding on site is limited and done by qualified welders. At 300 people, a fabrication workshop working to an execution standard, a coating contract and an inspection schedule for many structures become worthwhile.

Reference designs

Open for contributions Designs with drawings, specifications and a bill of materials. Add to it

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
CEN/TS 19101:2022 Design of fibre-polymer composite structuresStandardExternalWorkingS3Not stated on the page opened
EN 10025-2:2019 Hot rolled products of structural steels - Part 2: Technical delivery conditions for non-alloy structural steelsStandardExternalEstablishedS2Not stated on the page opened
EN 1090-2:2018+A1:2024 Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structuresStandardExternalEstablishedS3Not stated on the page opened
EN 1993 Eurocode 3: Design of steel structuresStandardExternalEstablishedS3Not stated on the page opened
EN 1999 Eurocode 9: Design of aluminium structuresStandardExternalEstablishedS3Not stated on the page opened
Health risks from welding, and Change in enforcement expectations for mild steel welding fumeGuideExternalEstablishedS2Not stated on the page opened
Categorising corrosivity by type of environmentGuideExternalEstablishedS0Not stated on the page opened
ISO 12944-1:2017 Paints and varnishes - Corrosion protection of steel structures by protective paint systems - Part 1: General introductionStandardExternalEstablishedS1Not stated on the page opened
ISO 1461:2022 Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methodsStandardExternalEstablishedS1Not stated on the page opened
Prospect for New Guidance in the Design of FRPPaperExternalNot assessedS3Not stated on the page opened

Depends on, and completes

Depends on 6.2, 6.5, 6.6.

It is one of 22 elements that complete Shelter and construction.

The standing questions

Who certifies welders and welds. Who repaints, and when. Who decides to replace a corroded member.

Environments

Environment profiles for these settings: Small islands and coasts; Arctic, subarctic and permafrost, including sea ice; Extreme cold. All environments

Safety

State and evidence

Drafted

An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.

Evidence from a real place or system is recorded here, with what did not work. What the states mean

History