Element 13.18
Sourcing reused servers, workstations and PCs
- Sheet
- 13.18
- Chapter
- 13 Digital infrastructure
- State
- Drafted
- Release
- 16 November 2026
- Editor
- Contributed by Praecise as open research
- Reviewers
- To be named at review
- Safety
- S1, as the chapter
- Licence
- CC BY-SA 4.0
- Resources
- 12
The element
- Requirement
The community obtains computers that others have retired, knows where each came from and that its previous owner's data is gone, and chooses only machines that can still run a supported operating system and the services it needs.
- How to tell
- Each machine has a record: where it came from, its date of manufacture, what was tested, and a statement that its storage was sanitised to a named method (NIST SP 800-88 Rev. 2, Guidelines for Media Sanitization).
- The processor supports hardware virtualisation where the machine will host virtual machines: Proxmox VE asks for an Intel VT or AMD-V capable processor and board (Proxmox VE System Requirements).
- The chosen operating system is inside its support life on that hardware. Proxmox VE states that each version is supported at least as long as its Debian base is supported by the Debian Security Team (Proxmox Virtual Environment).
- Its electricity use at idle and at load is known before it is accepted (see the power element).
- Options
- Enterprise servers retired by organisations. ENERGY STAR states that servers are typically replaced every three to five years (ENERGY STAR Enterprise Servers), so working machines leave service while still serviceable. A 2012 two-socket server measured 52.7 W at idle and 250 W at full load in its maker's benchmark (SPECpower_ssj2008 result: Dell PowerEdge R720 (Intel Xeon E5-2660), March 2012).
- Workstations and desktop PCs. Quieter and lower in power than rack servers, and suited to a first server for 30 adults (13.1).
- Through a certified refurbisher or recycler. e-Stewards certified processors state that they destroy all residual data on equipment they receive and are audited by third parties (e-Stewards). The R2 standard is a second certification; its publisher's site did not respond during this research, so it is not described here.
- Donations direct from an organisation. Cheapest, but the community must then sanitise the storage itself or ask for a written statement of the method used (NIST SP 800-88 Rev. 2, Guidelines for Media Sanitization).
- Where the law of the place supports it. In the European Union, servers placed on the market must offer a secure data deletion function and the maker must provide the latest firmware (Servers and data storage products: EU ecodesign requirements (Regulation (EU) 2019/424)), which helps a second owner.
- Settled, open, contested
Settled. Large quantities of working equipment leave service early (ENERGY STAR Enterprise Servers, The Global E-waste Monitor 2024). Open. How much carbon reuse saves for a given machine: estimates of embodied carbon vary widely with method, and the studies opened are modelling or vision papers, not measured lifecycle assessments of reused machines (Sustainability in HPC: Vision and Opportunities, Advancing Environmental Sustainability in Data Centers via Carbon Depreciation Models). Contested. Old against new: an older machine avoids new manufacture, while a newer one does far more work per watt (SPECpower_ssj2008 result: Dell PowerEdge R720 (Intel Xeon E5-2660), March 2012, SPECpower_ssj2008 result: ASUS RS720A-E12-RS12 (AMD EPYC 9754), November 2023). Where electricity is scarce or carbon-intensive the balance moves towards newer, more efficient machines.
The four stages
- Learn: why reuse matters: 62 million tonnes of electronic waste were generated in 2022 and 22.3 per cent was documented as collected and recycled (The Global E-waste Monitor 2024); embodied carbon can be about half of a computing centre's emissions where power is largely renewable (Sustainability in HPC: Vision and Opportunities).
- Design: list the services first (13.2), then the memory, storage and network needed (Proxmox VE System Requirements).
- Build: collect, record, test (see the testing element) and sanitise (NIST SP 800-88 Rev. 2, Guidelines for Media Sanitization, e-Stewards).
- Deploy: keep the record with the machine and review it each year against its power use (SPECpower_ssj2008 result: Dell PowerEdge R720 (Intel Xeon E5-2660), March 2012, SPECpower_ssj2008 result: ASUS RS720A-E12-RS12 (AMD EPYC 9754), November 2023).
Resources at each stage
1 Learn
Understand
- Advancing Environmental Sustainability in Data Centers via Carbon Depreciation Models Paper, S0
- Servers and data storage products: EU ecodesign requirements (Regulation (EU) 2019/424) Standard, S0
- The Global E-waste Monitor 2024 Paper, S0
- NIST SP 800-88 Rev. 2, Guidelines for Media Sanitization Standard, S1
- Sustainability in HPC: Vision and Opportunities Paper, S0
2 Design
Size and choose
- Dell EMC PowerEdge R740 Technical Specifications: environmental specifications Guide, S0
- e-Stewards Standard, S0
- ENERGY STAR Enterprise Servers Standard, S0
- Servers and data storage products: EU ecodesign requirements (Regulation (EU) 2019/424) Standard, S0
- NIST SP 800-88 Rev. 2, Guidelines for Media Sanitization Standard, S1
- Proxmox Virtual Environment Tool, S1
- Proxmox VE System Requirements Guide, S0
- SPECpower_ssj2008 result: ASUS RS720A-E12-RS12 (AMD EPYC 9754), November 2023 Dataset, S0
- SPECpower_ssj2008 result: Dell PowerEdge R720 (Intel Xeon E5-2660), March 2012 Dataset, S0
4 Deploy
Install, run and measure
- Dell EMC PowerEdge R740 Technical Specifications: environmental specifications Guide, S0
- e-Stewards Standard, S0
- ENERGY STAR Enterprise Servers Standard, S0
- NIST SP 800-88 Rev. 2, Guidelines for Media Sanitization Standard, S1
- Proxmox Virtual Environment Tool, S1
What changes between 30 adults and 300 people
At 30 adults one or two donated desktops or a single used server, chosen for low idle power, cover the services in 13.1. At 300 people the community needs at least two or three similar machines so that one can be repaired while others run; buying several of one model simplifies spare parts. No source opened gives figures per person.
Reference designs
Open for contributions Designs with drawings, specifications and a bill of materials. Add to it
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
| Resource | Type | Origin | Maturity | Safety | Licence, as stated at its source |
|---|---|---|---|---|---|
| Advancing Environmental Sustainability in Data Centers via Carbon Depreciation Models | Paper | External | Concept | S0 | Not stated on the page opened |
| Dell EMC PowerEdge R740 Technical Specifications: environmental specifications | Guide | External | Established | S0 | Not stated on the page opened |
| e-Stewards | Standard | External | Established | S0 | Not stated on the page opened |
| ENERGY STAR Enterprise Servers | Standard | External | Established | S0 | Not stated on the page opened |
| Servers and data storage products: EU ecodesign requirements (Regulation (EU) 2019/424) | Standard | External | Established | S0 | Not stated on the page opened |
| The Global E-waste Monitor 2024 | Paper | External | Established | S0 | Not stated on the page opened |
| NIST SP 800-88 Rev. 2, Guidelines for Media Sanitization | Standard | External | Established | S1 | Not stated on the page opened |
| Proxmox Virtual Environment | Tool | External | Established | S1 | GNU Affero General Public License, version 3 |
| Proxmox VE System Requirements | Guide | External | Established | S0 | Not stated on the page opened |
| SPECpower_ssj2008 result: ASUS RS720A-E12-RS12 (AMD EPYC 9754), November 2023 | Dataset | External | Established | S0 | Not stated on the page opened |
| SPECpower_ssj2008 result: Dell PowerEdge R720 (Intel Xeon E5-2660), March 2012 | Dataset | External | Established | S0 | Not stated on the page opened |
| Sustainability in HPC: Vision and Opportunities | Paper | External | Concept | S0 | Not stated on the page opened |
Depends on, and completes
It is one of 25 elements that complete Digital infrastructure.
The standing questions
Who can afford this: used machines cost little or nothing; the cost is electricity, time and spare parts. Who does the work: a keeper who records and tests every machine. Who decides: which donations to accept, and from whom, is a community decision (15.2).
Environments
- Islands and coasts: no source found on sourcing; shipping and spare parts are the practical limits.
- Arctic cold, hot deserts, tropical humid forest, high altitude: check the maker's stated operating range before accepting a machine; see the server room element (Dell EMC PowerEdge R740 Technical Specifications: environmental specifications).
- Temperate forest, flood plains, other harsh settings: no source found.
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.