The maker's environmental limits for a common two-socket server, an example of what such documentation states. Standard operation is 10 to 35 degrees C at 10 to 80 per cent relative humidity below 950 m with no direct sunlight; an expanded range runs to 40 degrees C for up to 10 per cent of annual hours and 45 degrees C for up to 1 per cent, with altitude derating. It also sets particulate and gaseous contamination limits: ISO 14644-1 Class 8 air, MERV11 or MERV13 filtration, no conductive or corrosive dust, and copper and silver coupon corrosion below 300 and 200 angstroms per month.

Go to the source

https://www.dell.com/support/manuals/en-us/poweredge-r740/per740_techspecs_pub/standard-operating-temperature?guid=guid-7c06327e-0776-43bd-8347-0604f24b1598&lang=en-us

Maintainer
Dell Technologies
Licence, as stated at its source
Not stated on the page opened
Open or commercial
Commercial
Maturity
EstablishedOur reading, 16 November 2026
Safety
S0
Review
Listed 16 November 2026by Public Protocol editors
Checked
16 November 2026
Next check due
16 May 2027
Steward
Public Protocol editors

Where it sits in the blueprint

Stages

Design, Deploy

Context

Climate, setting, scale, cost and skill: not stated in this entry. Check the source against your own place and numbers.

Verification

No verification is recorded on Public Platform for this entry. Records are added when someone reads it for accuracy, reviews it with a stated qualification, builds it or measures it.

Record

How it came in

Seed catalogue, 16 November 2026. Listed from Praecise open research. Three sections of the same manual were opened on the date shown: standard operating temperature, expanded operating temperature (https://www.dell.com/support/manuals/en-us/poweredge-r740/per740_techspecs_pub/expanded-operating-temperature?guid=guid-c1dd5cc4-87c1-4b9b-8606-f65caa48e23d&lang=en-us) and particulate and gaseous contamination specifications (https://www.dell.com/support/manuals/en-us/poweredge-r740/per740_techspecs_pub/particulate-and-gaseous-contamination-specifications?guid=guid-08e9c644-0cfa-409b-87d4-9492d229fa3e&lang=en-us).

Licence

Not stated on the page opened. Read at https://www.dell.com/support/manuals/en-us/poweredge-r740/per740_techspecs_pub/standard-operating-temperature?guid=guid-7c06327e-0776-43bd-8347-0604f24b1598&lang=en-us. How licences are recorded