Guide
Dell EMC PowerEdge R740 Technical Specifications: environmental specifications
External resource. Not made or verified by Public Protocol.
The maker's environmental limits for a common two-socket server, an example of what such documentation states. Standard operation is 10 to 35 degrees C at 10 to 80 per cent relative humidity below 950 m with no direct sunlight; an expanded range runs to 40 degrees C for up to 10 per cent of annual hours and 45 degrees C for up to 1 per cent, with altitude derating. It also sets particulate and gaseous contamination limits: ISO 14644-1 Class 8 air, MERV11 or MERV13 filtration, no conductive or corrosive dust, and copper and silver coupon corrosion below 300 and 200 angstroms per month.
https://www.dell.com/support/manuals/en-us/poweredge-r740/per740_techspecs_pub/standard-operating-temperature?guid=guid-7c06327e-0776-43bd-8347-0604f24b1598&lang=en-us
- Maintainer
- Dell Technologies
- Licence, as stated at its source
- Not stated on the page opened
- Open or commercial
- Commercial
- Maturity
- EstablishedOur reading, 16 November 2026
- Safety
- S0
- Review
- Listed 16 November 2026by Public Protocol editors
- Checked
- 16 November 2026
- Next check due
- 16 May 2027
- Steward
- Public Protocol editors
Where it sits in the blueprint
- Domains
- Stages
Design, Deploy
- Elements it supports
- Context
Climate, setting, scale, cost and skill: not stated in this entry. Check the source against your own place and numbers.
Verification
No verification is recorded on Public Platform for this entry. Records are added when someone reads it for accuracy, reviews it with a stated qualification, builds it or measures it.
Record
- How it came in
Seed catalogue, 16 November 2026. Listed from Praecise open research. Three sections of the same manual were opened on the date shown: standard operating temperature, expanded operating temperature (https://www.dell.com/support/manuals/en-us/poweredge-r740/per740_techspecs_pub/expanded-operating-temperature?guid=guid-c1dd5cc4-87c1-4b9b-8606-f65caa48e23d&lang=en-us) and particulate and gaseous contamination specifications (https://www.dell.com/support/manuals/en-us/poweredge-r740/per740_techspecs_pub/particulate-and-gaseous-contamination-specifications?guid=guid-08e9c644-0cfa-409b-87d4-9492d229fa3e&lang=en-us).
- Licence
Not stated on the page opened. Read at https://www.dell.com/support/manuals/en-us/poweredge-r740/per740_techspecs_pub/standard-operating-temperature?guid=guid-7c06327e-0776-43bd-8347-0604f24b1598&lang=en-us. How licences are recorded
- Something wrong?