The element
- Requirement
Sensors for motion, distance, gas and radiation are used within their documented range, temperature and supply, read through a known interface, and checked before their readings guide a machine or a person.
- How to tell
- The maker's figures are written beside each installed sensor: range, resolution, noise, temperature rating and current.
- Motion sensors: one six-axis inertial unit gives accelerometer ranges of 2 to 16 g, gyroscope ranges of 125 to 2,000 degrees per second, 685 microamps at full rate and -40 to 85 degrees C, with on-chip step and gesture recognition (Bosch Sensortec BMI270 inertial measurement unit).
- Ranging: a low-cost 2D lidar gives 0.15 to 12 m at 8,000 samples per second, rated 0 to 40 degrees C (Slamtec RPLIDAR A1); a stereo camera gives depth at a stated error by distance (Luxonis OAK-D Pro); a 60 to 64 GHz radar chip has reference designs for people counting and presence (Texas Instruments IWR6843 mmWave radar sensor).
- Gas: a photoacoustic CO2 sensor is specified over 400 to 5,000 ppm with accuracy of plus or minus 50 ppm plus a percentage of reading, 15 mA average current (Sensirion SCD41 CO2 sensor).
- Radiation: an open community kit logs dose rate with GPS every 5 seconds and shares to an open map (Safecast bGeigie Nano).
- Uncertainty is stated for any reading that decides acceptance or safety (JCGM publications: Guide to the expression of uncertainty in measurement (GUM) and International Vocabulary of Metrology (VIM)).
- Options
- Inertial units for balance, orientation, vibration and step counting (Bosch Sensortec BMI270 inertial measurement unit); vibration and sound together for machine health (MIMII Dataset: Sound Dataset for Malfunctioning Industrial Machine Investigation and Inspection).
- Lidar, stereo depth or radar for robot navigation and presence (Slamtec RPLIDAR A1, Luxonis OAK-D Pro, Texas Instruments IWR6843 mmWave radar sensor).
- Satellite positioning with RTK for machines that must hold a line in a field or on a site (RTKLIB, CentipedeRTK).
- Indoor air: CO2 as a marker of ventilation (Sensirion SCD41 CO2 sensor).
- Radiation surveys by volunteers (Safecast bGeigie Nano).
- Load cells, strain gauges, flow meters, magnetometers, spectrometers and touch sensors: no maker or evaluation page was opened in this work; see the research note.
- Settled, open, contested
Settled: makers' ratings are the outer limits; outside them, readings are not specified. Open: field drift of low-cost gas and motion sensors over years; no long-term evaluation was opened in this work. Contested: cheap many or expensive few. Many cheap sensors show spatial pattern; a few good ones give trusted values. Combining both is the WMO's advice for air (Integrating Low-Cost Sensor Systems and Networks to Enhance Air Quality Applications (GAW Report No. 293)).
The four stages
- Learn: JCGM publications: Guide to the expression of uncertainty in measurement (GUM) and International Vocabulary of Metrology (VIM) for uncertainty; each maker's page.
- Design: match range and temperature rating to the site (Bosch Sensortec BMI270 inertial measurement unit, Slamtec RPLIDAR A1, Texas Instruments IWR6843 mmWave radar sensor).
- Build: Safecast bGeigie Nano as an open kit; RTKLIB for positioning.
- Deploy: log readings with method and calibration date (22.7).
Resources at each stage
1 Learn
Understand
- JCGM publications: Guide to the expression of uncertainty in measurement (GUM) and International Vocabulary of Metrology (VIM) Standard, S0
- MIMII Dataset: Sound Dataset for Malfunctioning Industrial Machine Investigation and Inspection Dataset, S0
- Integrating Low-Cost Sensor Systems and Networks to Enhance Air Quality Applications (GAW Report No. 293) Guide, S0
2 Design
Size and choose
- JCGM publications: Guide to the expression of uncertainty in measurement (GUM) and International Vocabulary of Metrology (VIM) Standard, S0
- Bosch Sensortec BMI270 inertial measurement unit Reference design, S0
- Luxonis OAK-D Pro Reference design, S0
- MIMII Dataset: Sound Dataset for Malfunctioning Industrial Machine Investigation and Inspection Dataset, S0
- Sensirion SCD41 CO2 sensor Reference design, S0
- Slamtec RPLIDAR A1 Reference design, S0
- Texas Instruments IWR6843 mmWave radar sensor Reference design, S0
- Integrating Low-Cost Sensor Systems and Networks to Enhance Air Quality Applications (GAW Report No. 293) Guide, S0
3 Build
Build or obtain
- Bosch Sensortec BMI270 inertial measurement unit Reference design, S0
- CentipedeRTK Dataset, S0
- Luxonis OAK-D Pro Reference design, S0
- RTKLIB Tool, S0
- Safecast bGeigie Nano Reference design, S0
- Sensirion SCD41 CO2 sensor Reference design, S0
- Slamtec RPLIDAR A1 Reference design, S0
- Texas Instruments IWR6843 mmWave radar sensor Reference design, S0
4 Deploy
Install, run and measure
- CentipedeRTK Dataset, S0
- RTKLIB Tool, S0
- Safecast bGeigie Nano Reference design, S0
What changes between 30 adults and 300 people
At 30 adults, sensors are bought one at a time for a project, and the maker's sheet is the record. At 300 people, a stock of common sensors, a test bench with references and a register of what is installed where earn their place.
Reference designs
-
Reference design
Bosch Sensortec BMI270 inertial measurement unit
Maker's page for a low-power six-axis IMU: accelerometer ranges of 2 to 16 g, gyroscope ranges of 125 to 2,000 degrees per second, 685 microamps at full data rate, -40 to 85 degrees C, SPI and I2C, with on-chip motion, step and gesture recognition.
External resource. Not made or verified by Public ProtocolMaturity: EstablishedSafety S0CommercialListed 16 November 2026 -
Reference design
Maker's documentation for a stereo depth camera with on-board AI: two global-shutter mono cameras on a 7.5 cm baseline, a colour camera, an infrared dot projector and flood light, stated depth error below 2 percent under 4 m and below 6 percent at 7 to 10 m, 4 TOPS of on-board compute and up to 15 W draw.
External resource. Not made or verified by Public ProtocolMaturity: EstablishedSafety S0CommercialListed 16 November 2026 -
Reference design
Mobile, GPS-logging radiation sensor kit from the volunteer Safecast project, built to ride in a car window or on a bicycle and record a reading every 5 seconds with time and place. Logs are uploaded to the Safecast API and map; board files, cut templates and firmware are on GitHub, and a successor kit (bGeigieZen) is offered.
External resource. Not made or verified by Public ProtocolMaturity: ReplicatedSafety S0Open, with paid products or servicesListed 16 November 2026 -
Reference design
Maker's product page for a miniature photoacoustic NDIR carbon dioxide sensor with on-board temperature and humidity compensation: specified range 400 to 5,000 ppm, accuracy given as plus or minus 50 ppm plus a percentage of the reading, 2.4 to 5.5 V supply, 15 mA average current and -10 to 60 degrees C operation.
External resource. Not made or verified by Public ProtocolMaturity: EstablishedSafety S0CommercialListed 16 November 2026 -
Reference design
Maker's specification for a low-cost spinning 2D laser scanner used on small mobile robots: 0.15 to 12 m range, 1 degree or finer angular resolution, 8,000 samples per second, 5.5 Hz scan, 0.5 W, rated 0 to 40 degrees C, USB connection.
External resource. Not made or verified by Public ProtocolMaturity: EstablishedSafety S0CommercialListed 16 November 2026 -
Reference design
Texas Instruments IWR6843 mmWave radar sensor
Maker's page for a single-chip 60 to 64 GHz FMCW radar with on-chip DSP and hardware accelerator, rated -40 to 105 degrees C junction temperature, with reference designs for people counting, presence and gesture sensing and automated doors.
External resource. Not made or verified by Public ProtocolMaturity: EstablishedSafety S0CommercialListed 16 November 2026
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
| Resource | Type | Origin | Maturity | Safety | Licence, as stated at its source |
|---|---|---|---|---|---|
| JCGM publications: Guide to the expression of uncertainty in measurement (GUM) and International Vocabulary of Metrology (VIM) | Standard | External | Established | S0 | Copyright BIPM, all rights reserved (page footer); no open licence stated |
| Bosch Sensortec BMI270 inertial measurement unit | Reference design | External | Established | S0 | Not stated on the page opened |
| CentipedeRTK | Dataset | External | Replicated | S0 | CC BY-SA 4.0 (site content); Open Database License (network database) |
| Luxonis OAK-D Pro | Reference design | External | Established | S0 | Not stated on the page opened |
| MIMII Dataset: Sound Dataset for Malfunctioning Industrial Machine Investigation and Inspection | Dataset | External | Established | S0 | Not stated on the page opened |
| RTKLIB | Tool | External | Established | S0 | BSD 2-clause license with two additional exclusive clauses (versions to 2.4.1 under GPLv3) |
| Safecast bGeigie Nano | Reference design | External | Replicated | S0 | Website CC BY-NC 4.0; licence of the hardware files not stated on the page opened |
| Sensirion SCD41 CO2 sensor | Reference design | External | Established | S0 | Not stated on the page opened |
| Slamtec RPLIDAR A1 | Reference design | External | Established | S0 | Not stated on the page opened |
| Texas Instruments IWR6843 mmWave radar sensor | Reference design | External | Established | S0 | Not stated on the page opened |
| Integrating Low-Cost Sensor Systems and Networks to Enhance Air Quality Applications (GAW Report No. 293) | Guide | External | Established | S0 | Not stated on the page opened |
Depends on, and completes
It is one of 12 elements that complete Delivery, operations and measurement.
The standing questions
Who keeps the test references. Who decides that a sensor has drifted and must be replaced. Who reads the data.
Environments
inertial unit rated to -40 degrees C (Bosch Sensortec BMI270 inertial measurement unit); radar chip junction rated to -40 degrees C (Texas Instruments IWR6843 mmWave radar sensor); a CO2 sensor only to -10 degrees C (Sensirion SCD41 CO2 sensor); a low-cost lidar only to 0 degrees C (Slamtec RPLIDAR A1).
lidar rated to 40 degrees C (Slamtec RPLIDAR A1); CO2 sensor to 60 degrees C (Sensirion SCD41 CO2 sensor).
- Islands and coasts, tropical humid forest, temperate forest, high altitude, flood plains: no source found.
Environment profiles for these settings: Arctic, subarctic and permafrost, including sea ice; Extreme cold; Hot deserts; Extreme heat. All environments
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.