Requirement

Dissolved oxygen, temperature, pH and ammonia are measured often enough to act before fish suffer, with readings checked against a reference instrument and kept in the farm record (4.8).

How to tell

A measurement schedule exists for each pond, tank or cage, at least for oxygen and temperature. Readings are logged with time. Low-cost sensors are calibrated against a laboratory-grade meter at set intervals. Safe ranges for each species are taken from a species-specific source; this research found no open source giving such ranges across species, and the group should obtain them from its fish health contact or national fisheries agency. Field evidence shows why these matter: in semi-arid Tanzania, tilapia yield related to dissolved oxygen, turbidity, salinity and density (Pond water quality and fish yield in semi-arid Dodoma, Tanzania).

Options
Settled, open, contested

Settled: oxygen and temperature need frequent measurement; cheap sensors need calibration (Improved accuracy in IoT-based water quality monitoring for aquaculture tanks using low-cost sensors). Open: how computer vision results transfer between species and farms; the feeding model's abstract shows results on one species only (Three-stream convolutional network for classifying feeding intensity of farmed fish). Contested: automation. One position holds that sensors and control save fish and energy (An intelligent IoT-based predictive control system for water quality and energy management in koi aquaculture); the other that unattended systems fail silently, so daily human checks must remain.

The four stages

Resources at each stage

4 Deploy

Install, run and measure

What changes between 30 adults and 300 people

At 30 adults, a calibrated hand meter and a notebook may be enough, with one sensor node as an alarm. At 300 people, several units justify a sensor network, automatic aeration and a named person who calibrates and answers alarms.

Reference designs

Open for contributions Designs with drawings, specifications and a bill of materials. Add to it

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

Depends on, and completes

Depends on 4.8.

It is one of 27 elements that complete Food and farming.

The standing questions

Who can afford this: nodes are cheap; calibration solutions and reference meters are not. Who does the work: someone answers alarms at night. Who decides: the fish keeper sets alarm thresholds with the fish health contact.

Safety

State and evidence

Drafted

An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.

Evidence from a real place or system is recorded here, with what did not work. What the states mean

History