Public Protocol
Platform

Element 11.16

Choosing a structural material

Sheet
11.16
Chapter
11 Materials and supply
State
Drafted
Release
16 November 2026
Editor
Contributed by Praecise as open research
Reviewers
To be named at review
Safety
S3, as the chapter
Licence
CC BY-SA 4.0
Resources
13

The element

Requirement

Each structure is made of a material whose strength, durability and failure behaviour are known for the loads and climate of the site, chosen with a qualified engineer and under the code in force, with the material's own product and test standard named.

How to tell
Options

Timber and engineered timber. Light, renewable, needs to be kept dry and designed for fire (Wood handbook: Wood as an engineering material (FPL-GTR-282)). See the element on timber and bamboo structures. Bamboo. Round-culm bamboo for low buildings under ISO 22156 (ISO 22156:2021 Bamboo structures - Bamboo culms - Structural design). Steel and aluminium. Wide spans, towers and frames; needs corrosion protection (Categorising corrosivity by type of environment). Concrete, masonry and earth. Mass and compression; earth needs a dry plinth and roof (NZS 4297, 4298 and 4299:2024 Earth building standards). Fibre-reinforced polymers. Light and corrosion-resistant; a European design specification is new (see the steel and aluminium element). Reclaimed material. Lowest new carbon; needs assessment (see the reclaimed materials element).

Settled, open, contested

Settled: loads come first and are set by the code of the place; durability depends on exposure (EN 1991 Eurocode 1: Actions on structures, Categorising corrosivity by type of environment). Open: the Eurocodes are changing. The second generation was made available to national bodies up to 2026, with 2028 the latest date for withdrawing the first (Timeline for the Eurocodes second generation). Check which edition applies. Contested: local natural materials against code-listed industrial ones. The second have known properties; the first cost less in carbon and money and need testing or a special route through the code.

The four stages

Resources at each stage

What changes between 30 adults and 300 people

At 30 adults, buildings and fixtures are small and the simplest code class often applies; one material used well, with a known supplier, limits the skills needed. At 300 people, longer spans, assembly buildings, towers and bridges bring several materials, more load cases and formal checking, and a materials register becomes necessary.

Reference designs

  • Reference design

    Timeline for the Eurocodes second generation

    European Commission page giving the milestones of the second generation of the Eurocodes: first standards made available to national bodies in 2020, the last in 2026, and 2028 as the latest date of withdrawal of the first-generation standards.

    External resource. Not made or verified by Public ProtocolMaturity: WorkingSafety S0Open or commercial: not stated by the makerListed 16 November 2026

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
EN 350:2016 Durability of wood and wood-based products - Testing and classification of the durability to biological agentsStandardExternalEstablishedS1Not stated on the page opened
About the EN EurocodesStandardExternalEstablishedS3Not stated on the page opened
EN 1991 Eurocode 1: Actions on structuresStandardExternalEstablishedS3Not stated on the page opened
EN 1998 Eurocode 8: Design of structures for earthquake resistanceStandardExternalEstablishedS3Not stated on the page opened
Timeline for the Eurocodes second generationReference designExternalWorkingS0Not stated on the page opened
GEM Global Seismic Hazard MapDatasetExternalEstablishedS2CC BY-NC-SA 4.0 for downloads and viewer; CC BY-SA 4.0 for the PDF poster and PNG
ICE Database (Inventory of Carbon and Energy)DatasetExternalEstablishedS0Educational use only; must not be used for commercial applications
Categorising corrosivity by type of environmentGuideExternalEstablishedS0Not stated on the page opened
ISO 12494:2017 Atmospheric icing of structuresStandardExternalEstablishedS3Not stated on the page opened
ISO 22156:2021 Bamboo structures - Bamboo culms - Structural designStandardExternalEstablishedS3Not stated on the page opened
NZS 4297, 4298 and 4299:2024 Earth building standardsStandardExternalEstablishedS3Not stated on the page opened
ÖKOBAUDATDatasetExternalEstablishedS0Publicly available at no charge; licence terms in its data policy, not on the page opened
Wood handbook: Wood as an engineering material (FPL-GTR-282)GuideExternalEstablishedS2Not stated on the page opened

Depends on, and completes

Depends on 6.2, 6.5, 11.1.

It is one of 19 elements that complete Materials and supply.

The standing questions

Who pays for the engineer and the tests. Who keeps the record of what was used. Who decides when a cheaper material is good enough.

Safety

State and evidence

Drafted

An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.

Evidence from a real place or system is recorded here, with what did not work. What the states mean

History