Safety
S3, as the chapter
Licence
CC BY-SA 4.0
Resources
6

The element

Requirement

Where the community faces tornadoes, hurricanes or, in some countries, a duty to provide civil protection shelter, people have a place to go that is built to the public authority's criteria, kept ready, inspected, and known to everyone. Structure, ventilation, filtration, fire and air quality in shelters are safety level S3: this element states requirements and the authorities that set them, and gives no design or construction procedure.

How to tell

Storm safe rooms. In the United States, a safe room is a hardened structure built to FEMA's criteria, giving near-absolute protection, which FEMA defines as a very high probability that occupants are protected from injury or death FEMA Safe Rooms. The criteria are in FEMA P-361, Safe Rooms for Tornadoes and Hurricanes, for community and residential safe rooms; FEMA P-320 covers home safe rooms with construction drawings; the consensus standard for storm shelters is ICC 500, by the International Code Council and the National Storm Shelter Association, which FEMA's guidance references FEMA Safe Room Resources (P-361, P-320 and ICC 500). FEMA-funded projects follow the fifth edition of P-361 for declarations or funding notices on or after 31 March 2026, and FEMA recommends a licensed design professional FEMA Safe Rooms.

Civil protection shelters. Switzerland aims for a shelter place for every resident and has about 370,000 private and public shelters. Its shelters have a reinforced concrete shell, blast doors and an emergency exit, and a ventilation system with air intake, blast valve, pre-filter, blower and an NBC gas filter. Owners keep them clean and accessible, make them ready within five days, do not alter the shell, closures or ventilation, and leave technical equipment to specialists; authorities inspect at least every ten years, and small shelters over 40 years old need their ventilation and filters replaced Shelters for the population (Swiss Federal Office for Civil Protection). Sweden has about 64,000 shelters for about seven million people, to be ready within two days at heightened alert; they protect against blast, fragments, gases, radioactivity and biological agents but may not withstand a direct hit Civil defence shelters (Krisinformation.se, Sweden).

Options

A storm safe room inside a home or shared building. Fits tornado and hurricane regions; designed to P-361 or ICC 500 FEMA Safe Room Resources (P-361, P-320 and ICC 500).

A community safe room. Fits a settlement where not every building can have one FEMA Safe Room Resources (P-361, P-320 and ICC 500).

A civil protection shelter in a new building. Required by law in some countries; where it is not built, Switzerland charges a fee of CHF 1,400 per place towards public shelters Shelters for the population (Swiss Federal Office for Civil Protection).

A dual-use room. Swiss and Swedish shelters sit in ordinary buildings and are readied when needed Shelters for the population (Swiss Federal Office for Civil Protection) Civil defence shelters (Krisinformation.se, Sweden).

Settled, open, contested

Settled. Shelters are built to the authority's published criteria, maintained by the owner and inspected Shelters for the population (Swiss Federal Office for Civil Protection) FEMA Safe Rooms. Ventilation and filtration are not altered by occupants Shelters for the population (Swiss Federal Office for Civil Protection).

Open. Psychological effects of long stays in shelters, condensation in occupied shelters, and the cost of safe rooms: no open source was opened in this work.

Contested. Private shelters in every building or public shelters shared by an area; Switzerland uses both, financing public ones from fees Shelters for the population (Swiss Federal Office for Civil Protection).

The four stages

Learn: the authority's criteria FEMA Safe Rooms Shelters for the population (Swiss Federal Office for Civil Protection). Design: a licensed professional designs to the criteria FEMA Safe Rooms FEMA Safe Room Resources (P-361, P-320 and ICC 500). Build: components from the authority's approved list where one exists; Switzerland keeps a civil protection component database Shelters for the population (Swiss Federal Office for Civil Protection). Deploy: keep the shelter clean, accessible and stocked; Switzerland's page cites about one week of non-perishable food and 9 litres of water per person at home, and forbids cooking with alcohol or gas stoves in shelters Shelters for the population (Swiss Federal Office for Civil Protection); Sweden's lists what to bring for a stay of a couple of days Civil defence shelters (Krisinformation.se, Sweden); test radon in below-ground rooms Radon (WHO fact sheet).

Resources at each stage

What changes between 30 adults and 300 people

For 30 adults, one community safe room or shelter near the shared building may serve all, with a named keeper. For 300 people, places, routes and walking times are planned across the settlement; Swiss shelters for more than 30 people need permanent toilet booths Shelters for the population (Swiss Federal Office for Civil Protection), and readying shelters within the authority's time (five days in Switzerland, two in Sweden) becomes part of the community's emergency plan Shelters for the population (Swiss Federal Office for Civil Protection) Civil defence shelters (Krisinformation.se, Sweden).

Reference designs

Open for contributions Designs with drawings, specifications and a bill of materials. Add to it

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
Shelters for the population (Swiss Federal Office for Civil Protection)GuideExternalEstablishedS3Not stated on the page opened
FEMA Building Science: HurricanesLibraryExternalEstablishedS3Not stated on the page opened
FEMA Safe Room Resources (P-361, P-320 and ICC 500)LibraryExternalEstablishedS3Not stated on the page opened
FEMA Safe RoomsGuideExternalEstablishedS3Not stated on the page opened
Civil defence shelters (Krisinformation.se, Sweden)GuideExternalEstablishedS3Not stated on the page opened
Radon (WHO fact sheet)GuideExternalEstablishedS2Not stated on the page opened

Depends on, and completes

Depends on 6.2, 6.4.

It is one of 12 elements that complete Safety, resilience and disaster readiness.

The standing questions

Who pays for the shelter and its inspection. Who holds the keys and keeps it ready. Who decides who has a place.