Element 3.11
Reverse osmosis and membrane treatment
- Sheet
- 3.11
- Chapter
- 3 Water
- State
- Drafted
- Release
- 16 November 2026
- Editor
- Contributed by Praecise as open research
- Reviewers
- To be named at review
- Safety
- S3, as the chapter
- Licence
- CC BY-SA 4.0
- Resources
- 11
The element
- Requirement
Where a group uses reverse osmosis or another membrane process, the membrane is protected by pretreatment matched to the feedwater, its energy use and recovery are known, its concentrate is disposed of lawfully and without harm, and the product water is checked against the WHO Guidelines and national rules. Membrane treatment and the chemicals used with it are at safety level S3. This text points to the standards and makers' documentation; it gives no doses or operating procedure.
- How to tell
- Feedwater has been analysed and pretreatment chosen from it. One maker's manual gives a silt density index (SDI15) of at most 5 as the guideline and below 3 as recommended, and a free chlorine tolerance below 0.1 ppm for its membranes, with degradation after roughly 200 to 1,000 hours at 1 ppm (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)).
- Recovery is known. The same manual states that seawater plants are limited by the osmotic pressure of the concentrate to 30 to 45 per cent recovery, and that scaling is more of a problem in brackish plants, which run at higher recovery (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)). A review gives single-pass seawater recovery of up to 50 per cent (Energy Recovery in SWRO Desalination: Current Status and New Possibilities).
- Energy is metered. Seawater reverse osmosis needs 3.5 to 4.5 kWh per cubic metre (range 3 to 6.7); high-pressure pumps take about 65 per cent of it, at 55 to 70 bar (Energy Recovery in SWRO Desalination: Current Status and New Possibilities). For brackish water, a 2026 review states that process configuration and high-recovery operation dominate performance (Energy efficiency and sustainability of desalination); no open brackish figure was opened in this work.
- Cleaning is triggered by data: the manual says clean when normalised permeate flow drops 10 per cent or pressure drop rises 10 to 15 per cent (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)).
- Options
- Reverse osmosis: removes dissolved salts and many contaminants; WHO lists membrane techniques among arsenic removal methods (Arsenic (WHO fact sheet)).
- Nanofiltration: covered in the same maker manual for softening and organic removal (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)).
- Ultrafiltration and microfiltration: as pretreatment they can bring SDI below 1 (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)); as household filters, membrane products are among the types WHO has evaluated (WHO International Scheme to Evaluate Household Water Treatment Technologies).
- Electrodialysis: a battery-free solar electrodialysis system produced up to 5,000 litres a day from brackish groundwater in a six-month pilot (Solar-powered desalination system requires no extra batteries).
- Capacitive deionisation and forward osmosis: no primary source with field performance was opened in this work.
- Small units: the manual describes small single-element plants at about 25 per cent recovery whose elements are replaced after 1 to 2 years (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)).
- Graphene and other new membranes: laboratory stage (Graphene sieve turns seawater into drinking water); see the frontier notes.
- Settled, open, contested
Settled: pretreatment decides membrane life; residual free chlorine is removed before the membrane, as the maker's manual requires for its elements (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)). Open: remineralising permeate; WHO's 2011 desalination guidance covers it but could not be opened in this work. Taste and corrosion relate to total dissolved solids and pH (Secondary Drinking Water Standards: Guidance for Nuisance Chemicals). Contested: small units sending most of their feed to concentrate. At the 25 per cent recovery the manual gives for small preventively cleaned plants (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)), three litres go to concentrate for every litre of product. Some see that as acceptable for drinking water only; others as unacceptable where water is scarce. No open study weighing the two was opened in this work.
The four stages
Learn: osmosis, recovery, fouling and scaling (FilmTec Reverse Osmosis Membranes Technical Manual (version 20), Energy Recovery in SWRO Desalination: Current Status and New Possibilities). Design: feedwater analysis, pretreatment and recovery; open tools such as WaterTAP from NAWI model whole trains (National Alliance for Water Innovation (NAWI)). Build: certified equipment installed by a qualified supplier. Deploy: log pressures, flows and conductivity; clean on the triggers; plan concentrate disposal (The state of desalination and brine production: A global outlook).
Resources at each stage
1 Learn
Understand
- FilmTec Reverse Osmosis Membranes Technical Manual (version 20) Guide, S3
- The state of desalination and brine production: A global outlook Paper, S0
- Graphene sieve turns seawater into drinking water Paper, S0
- Solar-powered desalination system requires no extra batteries Paper, S0
- National Alliance for Water Innovation (NAWI) Framework, S0
- Energy Recovery in SWRO Desalination: Current Status and New Possibilities Paper, S0
- Secondary Drinking Water Standards: Guidance for Nuisance Chemicals Standard, S0
- Energy efficiency and sustainability of desalination Paper, S0
- Arsenic (WHO fact sheet) Guide, S3
- Guidelines for drinking-water quality Standard, S3
2 Design
Size and choose
- FilmTec Reverse Osmosis Membranes Technical Manual (version 20) Guide, S3
- The state of desalination and brine production: A global outlook Paper, S0
- National Alliance for Water Innovation (NAWI) Framework, S0
- Energy Recovery in SWRO Desalination: Current Status and New Possibilities Paper, S0
- Secondary Drinking Water Standards: Guidance for Nuisance Chemicals Standard, S0
- Arsenic (WHO fact sheet) Guide, S3
- Guidelines for drinking-water quality Standard, S3
- WHO International Scheme to Evaluate Household Water Treatment Technologies Standard, S3
3 Build
Build or obtain
4 Deploy
Install, run and measure
What changes between 30 adults and 300 people
For 30 adults, a point-of-use unit for drinking and cooking water only can serve, with elements replaced on the maker's schedule (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)). For 300 people, a skid system with pretreatment, energy recovery for seawater (Energy Recovery in SWRO Desalination: Current Status and New Possibilities), a trained operator and a consented concentrate outlet is needed.
Reference designs
Open for contributions Designs with drawings, specifications and a bill of materials. Add to it
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
| Resource | Type | Origin | Maturity | Safety | Licence, as stated at its source |
|---|---|---|---|---|---|
| FilmTec Reverse Osmosis Membranes Technical Manual (version 20) | Guide | External | Established | S3 | Not stated on the page opened |
| The state of desalination and brine production: A global outlook | Paper | External | Established | S0 | Not stated on the page opened |
| Graphene sieve turns seawater into drinking water | Paper | External | Concept | S0 | Not stated on the page opened |
| Solar-powered desalination system requires no extra batteries | Paper | External | Prototype | S0 | Not stated on the page opened |
| National Alliance for Water Innovation (NAWI) | Framework | External | Working | S0 | Not stated on the page opened |
| Energy Recovery in SWRO Desalination: Current Status and New Possibilities | Paper | External | Established | S0 | CC BY 4.0 |
| Secondary Drinking Water Standards: Guidance for Nuisance Chemicals | Standard | External | Established | S0 | Not stated on the page opened |
| Energy efficiency and sustainability of desalination | Paper | External | Not assessed | S0 | Not stated on the page opened |
| Arsenic (WHO fact sheet) | Guide | External | Established | S3 | Not stated on the page opened |
| Guidelines for drinking-water quality | Standard | External | Established | S3 | CC BY-NC-SA 3.0 IGO |
| WHO International Scheme to Evaluate Household Water Treatment Technologies | Standard | External | Established | S3 | Not stated on the page opened |
The standing questions
Who can afford this: membranes, energy and replacement elements are recurring costs. Who does the work: an operator who reads logs. Who decides: the regulator for concentrate discharge; the group for which uses get membrane water.
Environments
seawater from open intakes may cause biofouling without pretreatment (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)).
no source found.
brackish groundwater with solar electrodialysis (Solar-powered desalination system requires no extra batteries).
warm surface waters generally have higher biofouling potential than cold well waters (FilmTec Reverse Osmosis Membranes Technical Manual (version 20)).
no source found.
no source found.
no source found.
Environment profiles for these settings: Small islands and coasts; Arctic, subarctic and permafrost, including sea ice; Extreme cold; Hot deserts; Extreme heat; Tropical rainforest and humid tropics; High humidity; Temperate and boreal forests; Mountains and high altitude; River deltas and flood plains. All environments
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.