Element 6.9
Underground and earth-sheltered rooms: radon, damp and air
- Sheet
- 6.9
- Chapter
- 6 Shelter and construction
- State
- Drafted
- Release
- 16 November 2026
- Editor
- Contributed by Praecise as open research
- Reviewers
- To be named at review
- Safety
- S3, as the chapter
- Licence
- CC BY-SA 4.0
- Resources
- 6
The element
- Requirement
Any room below ground or covered by earth, whether a basement, an earth-sheltered house or a shelter, keeps out soil gas and water, stays above the temperature at which its surfaces grow mould, has air supplied and exhausted, and has a second way out. Excavation, retaining walls and the structure that holds back earth are safety level S3: a named engineer designs them, and this element gives no procedure.
- How to tell
Radon. The annual average indoor concentration is measured and compared with the WHO's recommended reference level of 100 Bq/m³, or no more than 300 Bq/m³ where 100 cannot be reached Radon (WHO fact sheet). Damp. Interior surfaces at every junction stay warm enough to avoid mould, the check the Passive House criteria make with a minimum temperature factor, which for parts in contact with the ground is taken against outdoor air temperature Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c). Flooding. Below-ground rooms in flood zones follow the flood rules, which treat space below the design flood level separately NFIP Technical Bulletins (FEMA). Air and exit. Civil protection shelters show the pattern at the strict end: a ventilation system and an emergency exit or escape tunnel Shelters for the population (Swiss Federal Office for Civil Protection).
- Options
Radon-resistant construction. The US EPA lists a gas-permeable layer under the slab, a soil-gas retarder, a vent pipe through the roof, sealed openings, and provision for a fan if testing after construction shows it is needed; it states including these at construction is typically cheaper than fixing a home afterwards Radon-Resistant Construction Basics and Techniques (US EPA). The WHO states tested, durable and cost-efficient prevention methods exist for new buildings Radon (WHO fact sheet).
Earth-sheltered house. Earth on walls or roof. It needs the same radon, damp, flood and exit measures as any room below ground. No open primary source on the thermal performance of earth-sheltered houses was found in this work.
Basement or semi-basement used as a shelter in peacetime. Sweden and Switzerland both place shelters in ordinary buildings, maintained by the owner and readied when needed Civil defence shelters (Krisinformation.se, Sweden) Shelters for the population (Swiss Federal Office for Civil Protection).
- Settled, open, contested
Settled. Radon causes an estimated 3 to 14% of lung cancers in a country Radon (WHO fact sheet); prevention at construction costs less than repair afterwards Radon-Resistant Construction Basics and Techniques (US EPA).
Open. Long-term comfort and psychological effects of living below ground: no open research source was found in this work.
Contested. No disagreement was documented in the sources opened.
The four stages
Learn: radon and its risks Radon (WHO fact sheet). Design: the engineer designs excavation and retaining structure; radon-resistant features are drawn in Radon-Resistant Construction Basics and Techniques (US EPA); junctions are checked for surface temperature Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c); flood level is read NFIP Technical Bulletins (FEMA). Build: features are inspected before the slab is cast. Deploy: test radon after occupation and act on the result Radon (WHO fact sheet) Radon-Resistant Construction Basics and Techniques (US EPA); check for damp after the first wet season.
Resources at each stage
1 Learn
Understand
- Shelters for the population (Swiss Federal Office for Civil Protection) Guide, S3
- NFIP Technical Bulletins (FEMA) Library, S3
- Civil defence shelters (Krisinformation.se, Sweden) Guide, S3
- Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c) Standard, S1
- Radon (WHO fact sheet) Guide, S2
2 Design
Size and choose
- Shelters for the population (Swiss Federal Office for Civil Protection) Guide, S3
- Radon-Resistant Construction Basics and Techniques (US EPA) Guide, S2
- NFIP Technical Bulletins (FEMA) Library, S3
- Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c) Standard, S1
- Radon (WHO fact sheet) Guide, S2
3 Build
Build or obtain
4 Deploy
Install, run and measure
What changes between 30 adults and 300 people
For 30 adults, one basement or earth-sheltered building can be checked room by room. For 300 people, radon testing becomes a programme across all buildings on radon-prone ground, and shared underground rooms such as stores and shelters need a named person responsible for ventilation and exits.
Reference designs
Open for contributions Designs with drawings, specifications and a bill of materials. Add to it
Parts list
Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.
| Resource | Type | Origin | Maturity | Safety | Licence, as stated at its source |
|---|---|---|---|---|---|
| Shelters for the population (Swiss Federal Office for Civil Protection) | Guide | External | Established | S3 | Not stated on the page opened |
| Radon-Resistant Construction Basics and Techniques (US EPA) | Guide | External | Established | S2 | Not stated on the page opened |
| NFIP Technical Bulletins (FEMA) | Library | External | Established | S3 | Not stated on the page opened |
| Civil defence shelters (Krisinformation.se, Sweden) | Guide | External | Established | S3 | Not stated on the page opened |
| Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c) | Standard | External | Established | S1 | This document is provided free of charge by the Passive House Institute (PHI). Digital copies may be distributed only in complete and in an unchanged form. Translations are only permitted after written agreement with the PHI. |
| Radon (WHO fact sheet) | Guide | External | Established | S2 | Not stated on the page opened |
Depends on, and completes
It is one of 22 elements that complete Shelter and construction.
The standing questions
Who pays for the engineer and the radon test. Who checks the ventilation. Who decides whether people may sleep below ground.
Environments
coastal flood zones follow the flood rules NFIP Technical Bulletins (FEMA); no source found on groundwater.
no source found.
no source found.
no source found.
no source found.
no source found.
space below flood level follows the flood rules NFIP Technical Bulletins (FEMA).
Other harsh settings
radon-prone areas, where the WHO stresses prevention during construction Radon (WHO fact sheet).
Environment profiles for these settings: Small islands and coasts; Arctic, subarctic and permafrost, including sea ice; Extreme cold; Hot deserts; Extreme heat; Tropical rainforest and humid tropics; High humidity; Temperate and boreal forests; Mountains and high altitude; River deltas and flood plains. All environments
Safety
State and evidence
Drafted
An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.
Evidence from a real place or system is recorded here, with what did not work. What the states mean
History
- Drafted in the release of 16 November 2026.