Public Protocol
Platform

Element 6.10

Building for extreme climates

Sheet
6.10
Chapter
6 Shelter and construction
State
Drafted
Release
16 November 2026
Editor
Contributed by Praecise as open research
Reviewers
To be named at review
Safety
S3, as the chapter
Licence
CC BY-SA 4.0
Resources
7

The element

Requirement

Where the climate is extreme, through deep cold and permafrost, great heat, heavy snow or high humidity, the building's foundation, envelope and services are chosen for that climate from published guidance, and the design names the climate data and future climate it assumes.

How to tell

The brief names the climate file used CBE Clima Tool. On permafrost, the foundation follows the national guidance in force: in Canada, four CSA Group documents developed between 2016 and 2021 cover infrastructure in permafrost (CSA PLUS 4011:19), foundations in permafrost (CSA PLUS 4011.1:19), thermosyphon foundations (CSA S500:21) and moderating thaw under existing buildings (CSA S501:21) Adaptation standards and guides for northern infrastructure and buildings in permafrost. In cold climates, indoor temperature is held within a published range; UNHCR gives 15 to 19 °C for emergency shelter in cold climates Emergency shelter standard. In hot or humid climates, hours above 25 °C and above 12 g/kg absolute humidity are counted against a limit, as the Passive House criteria do Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c). Snow loads are taken from the code's actions About the EN Eurocodes.

Options

On permafrost. Keep the ground frozen or allow for movement. The Canadian standards list site measures (grading, drainage, snow management, shading) and foundation measures (ventilated foundations, ground insulation, adjustable and levelling foundations, mechanical refrigeration and thermosyphons) Adaptation standards and guides for northern infrastructure and buildings in permafrost. A geotechnical engineer chooses among them.

In deep cold. A compact, highly insulated and airtight envelope with controlled ventilation, checked against climate data approved for the site Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c).

In hot, dry climates. Heavy walls that store the day's heat and lose it at night, in earth block or masonry Compressed Stabilised Earth Block; shading sized from sun angles CBE Clima Tool.

In hot, humid climates. Shade and air movement, or an envelope that limits humidity with dehumidification where the overheating and humidity limits demand it Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c).

Settled, open, contested

Settled. On permafrost the foundation type depends on keeping or managing the ground's thermal state, and thaw under existing buildings can be moderated Adaptation standards and guides for northern infrastructure and buildings in permafrost.

Open. Which climate scenario to design for over a building's life. Dust and sand in desert buildings: no open source found in this work.

Contested. Rely on heavy mass and night cooling in hot climates, or on insulation and mechanical cooling; each fits a different daily temperature swing Compressed Stabilised Earth Block Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c).

The four stages

Learn: the climate CBE Clima Tool; the regional standards Adaptation standards and guides for northern infrastructure and buildings in permafrost. Design: foundation by a geotechnical engineer on permafrost; envelope sized to the climate Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c); snow and wind to code About the EN Eurocodes. Build: work seasons follow the climate; on permafrost, the site measures chosen in design (grading, drainage, snow management, shading) are built with the foundation Adaptation standards and guides for northern infrastructure and buildings in permafrost. Deploy: monitor ground temperature and settlement under buildings on permafrost; log indoor temperature and humidity.

Resources at each stage

What changes between 30 adults and 300 people

Thirty adults can choose the best ground on a site and build compactly. Three hundred people need many building pads, roads and pipes, so ground conditions are mapped across the whole settlement, and shared buildings reduce the envelope per person in severe cold.

Reference designs

Open for contributions Designs with drawings, specifications and a bill of materials. Add to it

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
Compressed Stabilised Earth BlockGuideExternalEstablishedS3Humanity as a whole, No rights reserved
CBE Clima ToolToolExternalEstablishedS0MIT
Adaptation standards and guides for northern infrastructure and buildings in permafrostStandardExternalEstablishedS3Not stated on the page opened
About the EN EurocodesStandardExternalEstablishedS3Not stated on the page opened
NFIP Technical Bulletins (FEMA)LibraryExternalEstablishedS3Not stated on the page opened
Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c)StandardExternalEstablishedS1This document is provided free of charge by the Passive House Institute (PHI). Digital copies may be distributed only in complete and in an unchanged form. Translations are only permitted after written agreement with the PHI.
Emergency shelter standardStandardExternalEstablishedS2Not stated on the page opened

Depends on, and completes

Depends on 6.1, 6.2, 6.3.

It is one of 22 elements that complete Shelter and construction.

The standing questions

Who pays for ground investigation and monitoring. Who maintains thermosyphons or ventilated foundations. Who decides which future climate the design assumes.

Safety

State and evidence

Drafted

An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.

Evidence from a real place or system is recorded here, with what did not work. What the states mean

History