Public Protocol
Platform

Element 6.11

Interiors for health and function

Sheet
6.11
Chapter
6 Shelter and construction
State
Drafted
Release
16 November 2026
Editor
Contributed by Praecise as open research
Reviewers
To be named at review
Safety
S2, as the chapter
Licence
CC BY-SA 4.0
Resources
9

The element

Requirement

Rooms where people live, learn and work have enough daylight, quiet, clean air and accessible layout to support health, and their materials do not release harmful substances into the air. Each of these is checked against a published criterion.

How to tell

Daylight. The European standard EN 17037 is described in a 2023 paper as requiring at least 300 lx over half of the reference plane and 100 lx over 95% of it for more than half of daylight hours, with 500 and 750 lx for higher performance, and it also addresses view out, sunlight exposure and glare The practical implications of the EN 17037 minimum target daylight factor for building design and urban daylight in several European countries. Light for the body clock. CIE S 026 defines how to measure light for its non-visual effects; its page states it gives no recommended light levels CIE S 026/E:2018 System for Metrology of Optical Radiation for ipRGC-Influenced Responses to Light. Noise. The WHO's 2018 European guidelines, as summarised by the Norwegian Institute of Public Health, set average levels outside dwellings of Lden 53 dB and Lnight 45 dB for road traffic, 54 and 44 dB for railways and 45 and 40 dB for aircraft New noise guidelines from the World Health Organization (Norwegian Institute of Public Health). Air. Building products are chosen from emission-tested ranges, such as products tested under Germany's AgBB scheme, which assesses each emitted volatile compound against a health-based concentration and limits totals AgBB: Committee for Health-related Evaluation of Building Products; radon is measured against the WHO reference level of 100 Bq/m³ Radon (WHO fact sheet). Access. Shared rooms and routes meet the accessibility standard in force Access to and use of buildings: Approved Document M ADA Accessibility Standards.

Options

Daylight-led plans. Shallow rooms, windows sized from the daylight criterion; the paper examines what the criterion means for building design and urban daylight in several European countries The practical implications of the EN 17037 minimum target daylight factor for building design and urban daylight in several European countries.

Quiet by siting and envelope. Bedrooms on the quiet side and an airtight envelope with ventilation, so windows need not be opened to noise; overheating and humidity are then kept within limits by design Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c).

Low-emission material schedule. Specify tested products for floors, adhesives, boards and finishes AgBB: Committee for Health-related Evaluation of Building Products.

Small and multi-use rooms. Shared houses and small dwellings rely on rooms that change use. The WHO housing guidelines address crowding, temperature and accessibility WHO Housing and health guidelines. No open evidence base for multi-use interiors was found in this work.

Settled, open, contested

Settled. Radon has a WHO reference level Radon (WHO fact sheet); long exposure to road, rail and aircraft noise has WHO guideline values New noise guidelines from the World Health Organization (Norwegian Institute of Public Health).

Open. Light levels for the body clock: the measurement standard exists, recommended levels are not in it CIE S 026/E:2018 System for Metrology of Optical Radiation for ipRGC-Influenced Responses to Light.

Contested. Whether a single daylight criterion should apply to every regularly occupied room; the paper's authors criticise this The practical implications of the EN 17037 minimum target daylight factor for building design and urban daylight in several European countries.

The four stages

Resources at each stage

What changes between 30 adults and 300 people

For 30 adults, one shared house can be planned room by room with every bedroom on a quiet, daylit side. For 300 people, daylight to lower floors depends on the spacing of buildings across the site The practical implications of the EN 17037 minimum target daylight factor for building design and urban daylight in several European countries, noise sources such as roads and workshops are placed in the settlement plan, and a common materials list keeps emission testing manageable.

Reference designs

Open for contributions Designs with drawings, specifications and a bill of materials. Add to it

Parts list

Every resource that supports this element. Those marked External carry the label “External resource. Not made or verified by Public Protocol”.

ResourceTypeOriginMaturitySafetyLicence, as stated at its source
ADA Accessibility StandardsStandardExternalEstablishedS1Not stated on the page opened
AgBB: Committee for Health-related Evaluation of Building ProductsStandardExternalEstablishedS1Not stated on the page opened
Access to and use of buildings: Approved Document MStandardExternalEstablishedS1Open Government Licence v3.0
CIE S 026/E:2018 System for Metrology of Optical Radiation for ipRGC-Influenced Responses to LightStandardExternalEstablishedS0Not stated on the page opened
New noise guidelines from the World Health Organization (Norwegian Institute of Public Health)GuideExternalEstablishedS0Not stated on the page opened
The practical implications of the EN 17037 minimum target daylight factor for building design and urban daylight in several European countriesPaperExternalNot assessedS0CC BY-NC-ND 4.0
Criteria for Buildings: Passive House, EnerPHit, PHI Low Energy Building (Version 10c)StandardExternalEstablishedS1This document is provided free of charge by the Passive House Institute (PHI). Digital copies may be distributed only in complete and in an unchanged form. Translations are only permitted after written agreement with the PHI.
WHO Housing and health guidelinesGuideExternalEstablishedS1CC BY-NC-SA 3.0 IGO
Radon (WHO fact sheet)GuideExternalEstablishedS2Not stated on the page opened

Depends on, and completes

Depends on 6.1, 6.3, 6.4, 6.8.

It is one of 22 elements that complete Shelter and construction.

The standing questions

Who pays for tested materials. Who measures air and radon after people move in. Who decides how much daylight is traded for density.

Safety

State and evidence

Drafted

An editor has written the element's text from the resources listed under it, citing them. It is checked when it is reviewed.

Evidence from a real place or system is recorded here, with what did not work. What the states mean

History